Atomic spectrometry update. Industrial analysis: metals, chemicals and advanced materials

被引:18
作者
Fisher, A
Hinds, MW
Nelms, SN
Penny, DM
Goodall, P
机构
[1] Univ Plymouth, Sch Environm Sci, Plymouth PL4 8AA, Devon, England
[2] Royal Canadian Mint, Ottawa, ON K1A 0G8, Canada
[3] Thermo Elemental, Winsford CW7 3BX, Cheshire, England
[4] Shell Res & Technol Ctr, Chester CH1 3SH, Cheshire, England
[5] BNFL, Seascale C120 1PG, Cumbria, England
关键词
D O I
10.1039/b210974n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This Atomic Spectrometry Update is the latest in an annual series under the title 'Industrial Analysis'. The job of topic group co-ordinator has passed from Ben Fairman to Andy Fisher but, other than that, the writing team has stayed the same. The general structure of the review is the same as last year, but there has been an attempt to reduce the size of the tables and to be more descriptive and critical in the text instead. The use of techniques capable of analysing solid materials directly has increased greatly for the analysis of metals during this review period. Therefore, techniques such as LIBS, laser ablation, glow discharge and X-ray fluorescence have all proved popular. The determination of S and Hg in petroleum products and in coals, respectively, has proved to be the most popular area of interest in these materials in this review period. Similarly, there have been a large number of applications that have used funtionalised resins to either pre-concentrate analytes or to separate the matrix during the analysis of samples. There has been a noticeable increase in the number of papers reporting the use of multi-collector ICP-MS during the analysis of inorganic materials. Also noticeable is the predominance of solid sampling techniques such as ETV and LA. The solid sampling theme is also prevalent in the analysis of advanced materials. Here, techniques such as laser ablation, TRXRF and slurry introduction have proved to be popular, since they do not require dissolution/digestion of the samples, which for many of these sample types can be problematical. The catalysts section has seen a significant increase in the number of relevant abstracts when compared with last year. It is also noticeable that for many of the advanced materials, the abstracts indicate that an atomic spectrometric technique has been used, but that details of sample preparation and of results are very scarce.
引用
收藏
页码:1624 / 1649
页数:26
相关论文
共 381 条
[11]   EDXRF study of Tupi-Guarani archaeological ceramics [J].
Appoloni, CR ;
Quiñones, FRE ;
Aragao, PHA ;
dos Santos, AO ;
da Silva, LM ;
Barbieri, PF ;
do Nascimento, VF ;
Coimbra, MM .
RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) :711-712
[12]   Chemical separation and ICP-AES determination of 22 metallic elements in U and Pu matrices using cyanex-923 extractant and studies on stripping of U and Pu [J].
Argekar, AA ;
Kulkarni, MJ ;
Mathur, JN ;
Page, AG .
TALANTA, 2002, 56 (04) :591-601
[13]   Tin soaps in emulsion PVC heat stabilization [J].
Arkis, E ;
Balköse, D .
ADVANCES IN POLYMER TECHNOLOGY, 2002, 21 (01) :65-73
[14]   Determination of very low levels of dissolved mercury(II) and methylmercury in river waters by continuous flow with on-line UV decomposition and cold-vapor atomic fluorescence spectrometry after pre-concentration on a silica gel-2-mercaptobenzimidazol sorbent [J].
Bagheri, H ;
Gholami, A .
TALANTA, 2001, 55 (06) :1141-1150
[15]   Stress-induced transformation of defects in homoepitaxial beryllium-doped GaAs thin films [J].
Bak-Misiuk, J ;
Misiuk, A ;
Zhuravlev, KS ;
Domagala, JZ ;
Adamczewska, J ;
Preobrazhenskii, VV .
PHYSICA B-CONDENSED MATTER, 2001, 308 :820-822
[16]  
Banno Y, 2000, SOL ST PHEN, V78-79, P275
[17]   Effects of experimental parameters in quantitative analysis of steel alloy by laser-induced breakdown spectroscopy [J].
Bassiotis, I ;
Diamantopoulou, A ;
Giannoudakos, A ;
Roubani-Kalantzopoulou, F ;
Kompitsas, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (06) :671-683
[18]   Recent advances and perspectives in synchrotron radiation TXRF [J].
Baur, K ;
Brennan, S ;
Werho, D ;
Moro, L ;
Pianetta, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :1198-1201
[19]  
Becker JS, 2002, ATOM SPECTROSC, V23, P1
[20]   Studies of LA-ICP-MS on quartz glasses at different wavelengths of a Nd:YAG laser [J].
Becker, JS ;
Tenzler, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :637-640