Management of Lung Nodules Detected by Volume CT Scanning

被引:651
作者
van Klaveren, Rob J. [1 ]
Oudkerk, Matthijs [3 ]
Prokop, Mathias [7 ]
Scholten, Ernst T. [10 ]
Nackaerts, Kristiaan [14 ]
Vernhout, Rene [1 ]
van Iersel, Carola A. [1 ,2 ]
van den Bergh, Karien A. M. [2 ]
van't Westeinde, Susan [1 ]
van der Aalst, Carlijn [1 ,2 ]
Thunnissen, Erik [13 ]
Xu, Dong Ming [3 ]
Wang, Ying [3 ]
Zhao, Yingru [3 ]
Gietema, Hester A. [7 ]
de Hoop, Bart-Jan [7 ]
Groen, Harry J. M. [5 ]
de Bock, Geertruida H. [4 ]
van Ooijen, Peter [3 ]
Weenink, Carla [11 ]
Verschakelen, Johny [15 ]
Lammers, Jan-Willem J. [8 ]
Timens, Wim [6 ]
Willebrand, Dik [12 ]
Vink, Aryan [9 ]
Mali, Willem [7 ]
de Koning, Harry J. [2 ]
机构
[1] Erasmus MC, Dept Pulmonol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Publ Hlth, NL-3000 CA Rotterdam, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, NL-9713 AV Groningen, Netherlands
[4] Univ Med Ctr Groningen, Dept Epidemiol, NL-9713 AV Groningen, Netherlands
[5] Univ Med Ctr Groningen, Dept Pulmonol, NL-9713 AV Groningen, Netherlands
[6] Univ Med Ctr Groningen, Dept Pathol, NL-9713 AV Groningen, Netherlands
[7] Univ Med Ctr, Dept Radiol, Utrecht, Netherlands
[8] Univ Med Ctr, Dept Pulmonol, Utrecht, Netherlands
[9] Univ Med Ctr, Dept Pathol, Utrecht, Netherlands
[10] Kennemer Gasthuis, Dept Radiol, Haarlem, Netherlands
[11] Kennemer Gasthuis, Dept Pulmonol, Haarlem, Netherlands
[12] Kennemer Gasthuis, Dept Pathol, Haarlem, Netherlands
[13] Free Univ Amsterdam, Med Ctr, Dept Pathol, Amsterdam, Netherlands
[14] Univ Hosp Gasthuisberg, Dept Pulmonol, B-3000 Louvain, Belgium
[15] Univ Hosp Gasthuisberg, Dept Radiol, B-3000 Louvain, Belgium
关键词
POSITRON-EMISSION-TOMOGRAPHY; COMPUTED-TOMOGRAPHY; PULMONARY NODULES; SPIRAL CT; RANDOMIZED FEASIBILITY; SCREENING-PROGRAM; GROWTH-RATE; DOSE CT; CANCER; TRIAL;
D O I
10.1056/NEJMoa0906085
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The use of multidetector computed tomography (CT) in lung-cancer screening trials involving subjects with an increased risk of lung cancer has highlighted the problem for the clinician of deciding on the best course of action when noncalcified pulmonary nodules are detected by CT. METHODS A total of 7557 participants underwent CT screening in years 1, 2, and 4 of a randomized trial of lung-cancer screening. We used software to evaluate a noncalcified nodule according to its volume or volume-doubling time. Growth was defined as an increase in volume of at least 25% between two scans. The first-round screening test was considered to be negative if the volume of a nodule was less than 50 mm(3), if it was 50 to 500 mm3 but had not grown by the time of the 3-month follow-up CT, or if, in the case of those that had grown, the volume-doubling time was 400 days or more. RESULTS In the first and second rounds of screening, 2.6% and 1.8% of the participants, respectively, had a positive test result. In round one, the sensitivity of the screen was 94.6% (95% confidence interval [CI], 86.5 to 98.0) and the negative predictive value 99.9% (95% CI, 99.9 to 100.0). In the 7361 subjects with a negative screening result in round one, 20 lung cancers were detected after 2 years of follow-up. CONCLUSIONS Among subjects at high risk for lung cancer who were screened in three rounds of CT scanning and in whom noncalcified pulmonary nodules were evaluated according to volume and volume-doubling time, the chances of finding lung cancer 1 and 2 years after a negative first-round test were 1 in 1000 and 3 in 1000, respectively. (Current Controlled Trials number, ISRCTN63545820.)
引用
收藏
页码:2221 / 2229
页数:9
相关论文
共 38 条
[1]  
AANDERIJN A, 2004, CBO GUIDELINE NONSMA
[2]   Computed tomography screening for lung cancer - Review of screening principles and update on current status [J].
Black, William C. .
CANCER, 2007, 110 (11) :2370-2384
[3]   Baseline results of the Depiscan study: A French randomized pilot trial of lung cancer screening comparing dose CT scan (LDCT) and chest X-ray (CXR) [J].
Blanchon, Thierry ;
Brechot, Jeanne-Marie ;
Grenier, Philippe A. ;
Ferretti, Gilbert R. ;
Lemarie, Etienne ;
Milleron, Bernard ;
Chague, Dorninique ;
Laurent, Franqois ;
Martineti, Yves ;
Beigelman-Aubry, Catherine ;
Blanchon, Franois ;
Revel, Marie-Pierre ;
Friard, Sylvie ;
Remy-Jardin, Martine ;
Vasile, Manuela ;
Santelmo, Nicola ;
Lecalier, Alain ;
Lefebure, Patricia ;
Moro-Sibilot, Denis ;
Breton, Jean-Luc ;
Carette, Marie-France ;
Brambilla, Christian ;
Fournel, Francois ;
Kieffer, Alexia ;
Frija, Guy ;
Flahault, Antoine .
LUNG CANCER, 2007, 58 (01) :50-58
[4]   Precision of computer-aided volumetry of artificial small solid pulmonary nodules in ex vivo porcine lungs [J].
Bolte, H. ;
Riede, C. ;
Mueller-Huelsbeck, S. ;
Freitag-Wolf, S. ;
Kohl, G. ;
Drews, T. ;
Heller, M. ;
Bieder, J. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954) :414-421
[5]   Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness [J].
Fischbach, F ;
Knollmann, F ;
Griesshaber, V ;
Freund, T ;
Akkol, E ;
Felix, R .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2378-2383
[6]   Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT-influence of inspiration level, nodule size, and segmentation performance [J].
Gietema, Hester A. ;
Schaefer-Prokop, Cornelia M. ;
Mali, Willem P. T. M. ;
Groenewegen, Gerard ;
Prokop, Mathias .
RADIOLOGY, 2007, 245 (03) :888-894
[7]   Baseline findings of a randomized feasibility trial of lung cancer screening with spiral CT scan vs chest radiograph - The Lung Screening Study of the National Cancer Institute [J].
Gohagan, J ;
Marcus, P ;
Fagerstrom, R ;
Pinsky, P ;
Kramer, B ;
Prorok, P .
CHEST, 2004, 126 (01) :114-121
[8]   Final results of the Lung Screening Study, a randomized feasibility study of spiral CT versus chest X-ray screening for lung cancer [J].
Gohagan, JK ;
Marcus, PM ;
Fagerstrom, RM ;
Pinsky, PF ;
Kramer, BS ;
Prorok, PC ;
Ascher, S ;
Bailey, W ;
Brewer, B ;
Church, T ;
Engelhard, D ;
Ford, M ;
Fouad, M ;
Freedman, M ;
Gelmann, E ;
Gierada, D ;
Hocking, W ;
Inampudi, S ;
Irons, B ;
Johnson, CC ;
Jones, A ;
Kucera, G ;
Kvale, P ;
Lappe, K ;
Manor, W ;
Moore, A ;
Nath, H ;
Neff, S ;
Oken, M ;
Plunkett, M ;
Price, H ;
Reding, D ;
Riley, T ;
Schwartz, M ;
Spizarny, D ;
Yoffie, R ;
Zylak, C .
LUNG CANCER, 2005, 47 (01) :9-15
[9]   Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements [J].
Goodman, LR ;
Gulsun, M ;
Washington, L ;
Nagy, PG ;
Piacsek, KL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (04) :989-994
[10]  
Henschke CI, 2008, NEW ENGL J MED, V358, P1875