Multiple open-channel electroosmotic pumping system for microfluidic sample handling

被引:125
作者
Lazar, IM [1 ]
Karger, BL [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
关键词
D O I
10.1021/ac0203950
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a novel, fully integrated, miniaturized pumping system for generation of pressure-driven flow in microfluidic platforms is described. The micropump, based on electroosmotic pumping principles, has a multiple open-channel configuration consisting of hundreds of parallel, small-diameter microchannels. Specifically, pumps with microchannels of 1-6 mum in depth, 4-50 nun in length, and an overall area of a few square millimeters, were constructed. Flow rates of 10-400 nL/min were generated in electric-field-free regions in a stable, reproducible and controllable manner. In addition, eluent gradients were created by simultaneously using two pumps. Pressures up to 80 psi were produced with the present pump configurations. The pump can be easily interfaced with other operational elements of a micrototal analysis system (mu-TAS) device with multiplexing capabilities. A new microfluidic valving system was also briefly evaluated in conjunction with these pumps. The micropump was utilized to deliver peptide samples for electro-spray ionization-mass spectrometric (ESI-MS) detection.
引用
收藏
页码:6259 / 6268
页数:10
相关论文
共 46 条
[1]   Modelling of micropumps using unimorph piezoelectric actuator and ball valves [J].
Accoto, D ;
Carrozza, MC ;
Dario, P .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2000, 10 (02) :277-281
[2]   ELECTROOSMOSIS - A RELIABLE FLUID PROPULSION SYSTEM FOR FLOW-INJECTION ANALYSIS [J].
DASGUPTA, PK ;
LIU, S .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1792-1798
[3]   Microfabricated centrifugal microfluidic systems: Characterization and multiple enzymatic assays [J].
Duffy, DC ;
Gillis, HL ;
Lin, J ;
Sheppard, NF ;
Kellogg, GJ .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4669-4678
[4]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[5]   Enhancement of elementary displaced volume with electrostatically actuated diaphragms: application to electrostatic micropumps [J].
Francais, O ;
Dufour, I .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2000, 10 (02) :282-286
[6]   Design, optimization and simulation on microelectromagnetic pump [J].
Gong, QL ;
Zhou, ZY ;
Yang, YH ;
Wang, XH .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 83 (1-3) :200-207
[7]   Partial electroosmotic pumping in complex capillary systems -: Part 2:: Fabrication and application of a micro total analysis system (μTAS) suited for continuous volumetric nanotitrations [J].
Guenat, OT ;
Ghiglione, D ;
Morf, WE ;
de Rooij, NF .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) :273-282
[8]   On-chip thermopneumatic pressure for discrete drop pumping [J].
Handique, K ;
Burke, DT ;
Mastrangelo, CH ;
Burns, MA .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1831-1838
[9]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[10]   A picoliter-volume mixer for microfluidic analytical systems [J].
He, B ;
Burke, BJ ;
Zhang, X ;
Zhang, R ;
Regnier, FE .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :1942-1947