Multitrack electrospray chips

被引:26
作者
Dayon, Loic [1 ]
Abonnenc, Melanie [1 ]
Prudent, Michel [1 ]
Lion, Niels [1 ]
Girault, Hubert H. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Electrochem Phys & Analyt, Stn 6, CH-1015 Lausanne, Switzerland
来源
JOURNAL OF MASS SPECTROMETRY | 2006年 / 41卷 / 11期
关键词
chip; electrospray; emitter; mass spectrometry; quantification; sequential; source; tagging;
D O I
10.1002/jms.1119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multitrack electrospray chips (MTEC) were fabricated by UV-photoablation of polyethylene terephthalate (PET) substrates. They are composed of an array of up to six microchannels that are successively used as electrospray ionization (ESI) emitters for mass spectrometry (MS). There is no requirement for alignment of the different spraying microchannels with the mass spectrometer orifice. The MTEC is thus fixed in front of the mass spectrometer and the successive MS analyses are performed without moving the chip. The sequential electrospraying by successive application of an identical high voltage in each off-axis microchannel was evaluated for the fast screening of peptides and proteins. The counting of cysteines in peptides through chemical modification and the relative quantification of a peptide in two samples are presented herein as two original strategies based on this new analytical tool. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1484 / 1490
页数:7
相关论文
共 21 条
[11]   Microfluidic systems in proteomics [J].
Lion, N ;
Rohner, TC ;
Dayon, L ;
Arnaud, IL ;
Damoc, E ;
Youhnovski, N ;
Wu, ZY ;
Roussel, C ;
Josserand, J ;
Jensen, H ;
Rossier, JS ;
Przybylski, M ;
Girault, HH .
ELECTROPHORESIS, 2003, 24 (21) :3533-3562
[12]   Development of multichannel devices with an array of electrospray tips far high-throughput mass spectrometry [J].
Liu, HH ;
Felten, C ;
Xue, QF ;
Zhang, BL ;
Jedrzejewski, P ;
Karger, BL ;
Foret, F .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3303-3310
[13]   Structure specific chromatographic selection in targeted proteomics [J].
Mirzaei, H ;
Regnier, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (01) :23-34
[14]   Gravity-induced convective flow in microfluidic systems: Electrochemical characterization and application to enzyme-linked immunosorbent assay tests [J].
Morier, P ;
Vollet, C ;
Michel, PE ;
Reymond, F ;
Rossier, JS .
ELECTROPHORESIS, 2004, 25 (21-22) :3761-3768
[15]   Dual electrospray ionization source for confident generation of accurate mass tags using liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry [J].
Nepomuceno, AI ;
Muddiman, DC ;
Bergen, HR ;
Craighead, JR ;
Burke, MJ ;
Caskey, PE ;
Allan, JA .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3411-3418
[16]   UV laser machined polymer substrates for the development of microdiagnostic systems [J].
Roberts, MA ;
Rossier, JS ;
Bercier, P ;
Girault, H .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2035-2042
[17]   Accurate mass measurement in nano-electrospray ionization mass spectrometry by alternate switching of high voltage between sample and reference sprayers [J].
Satomi, Y ;
Kudo, Y ;
Sasaki, K ;
Hase, T ;
Takao, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (04) :540-546
[18]   Modification of cysteine residues by alkylation. A tool in peptide mapping and protein identification [J].
Sechi, S ;
Chait, BT .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5150-5158
[19]   SELF-DEVELOPING PHOTOETCHING OF POLY(ETHYLENE-TEREPHTHALATE) FILMS BY FAR ULTRAVIOLET EXCIMER LASER-RADIATION [J].
SRINIVASAN, R ;
MAYNEBANTON, V .
APPLIED PHYSICS LETTERS, 1982, 41 (06) :576-578
[20]   Pulsed dual electrospray ionization for ion/ion reactions [J].
Xia, Y ;
Liang, XR ;
McLuckey, SA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (11) :1750-1756