Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: Comparison with left ventricular angiography

被引:58
作者
Ichikawa, Y
Sakuma, H
Kitagawa, K
Ishida, N
Takeda, K
Uemura, S
Motoyasu, M
Nakano, T
Nozaki, A
机构
[1] Mie Univ, Sch Med, Dept Radiol, Tsu, Mie 5148507, Japan
[2] Mie Univ, Sch Med, Dept Internal Med, Tsu, Mie 5148507, Japan
[3] GE Yokogawa Med Syst Asia, Hachioji, Tokyo, Japan
关键词
left ventricular function; magnetic resonance imaging; steady-state free precession; left ventricular angiography;
D O I
10.1081/JCMR-120019422
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous studies demonstrated that magnetic resonance (MR) imaging consistently underestimated angiographic measurements of left ventricular (LV) volumes. The purpose of this study was to determine whether MR imaging with steady-state free precession acquisition (SSFP) can provide improved accuracy and reproducibility in measuring cardiac function in comparison with fast spoiled gradient echo cine MR imaging (SPGR). Twenty patients with cardiovascular diseases who underwent breath-hold cine MR imaging within one week of LV angiography were studied. Two sets of breath-hold cine MR images were obtained, one with SSFP and another with SPGR. The LV volumes determined by two breath-hold cine MR sequences were compared with the results by LV angiography. SPGR cine MR imaging consistently underestimated angiographic LV volumes. The mean difference of LV end-diastolic volume was -22.5 +/- 14.8 ml (p < 0.001) for short-axis planes and -27.7 +/- 21.5 ml (p < 0.001) for long-axis planes. In contrast, LV volumes measured by the SSFP imaging showed a good agreement with the results by angiography. The mean difference of LV end-diastolic volume was -2.5 +/- 14.3 ml (p = N.S.) for short-axis planes and -10.9 +/- 15.1 ml (p < 0.01) for long-axis planes. Standard error of the estimation in measuring LV end-diastolic volume with the SSFP imaging was 3.9% for short-axis images and 4.9% for long-axis images. These values were 7.2% and 8.7% with the SPGR imaging. In conclusion, the SSFP acquisition can provide accurate and noninvasive assessments of LV volumes and ejection fraction within a reduced imaging time.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 32 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[3]   Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle [J].
Bloomer, TN ;
Plein, S ;
Radjenovic, A ;
Higgins, DM ;
Jones, TR ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) :685-692
[4]   GATED CARDIAC MRI - EJECTION-FRACTION DETERMINATION USING THE RIGHT ANTERIOR OBLIQUE VIEW [J].
BUCKWALTER, KA ;
AISEN, AM ;
DILWORTH, LR ;
MANCINI, GBJ ;
BUDA, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (01) :33-37
[5]   NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE [J].
BUSER, PT ;
AUFFERMANN, W ;
HOLT, WW ;
WAGNER, S ;
KIRCHER, B ;
WOLFE, C ;
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1294-1300
[6]   Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction - Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging [J].
Chuang, ML ;
Hibberd, MG ;
Salton, CJ ;
Beaudin, RA ;
Riley, MF ;
Parker, RA ;
Douglas, PS ;
Manning, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) :477-484
[7]   LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY [J].
CRANNEY, GB ;
LOTAN, CS ;
DEAN, L ;
BAXLEY, W ;
BOUCHARD, A ;
POHOST, GM .
CIRCULATION, 1990, 82 (01) :154-163
[8]   USEFULNESS AND LIMITATIONS OF RADIOGRAPHIC METHODS FOR DETERMINING LEFT VENTRICULAR VOLUME [J].
DODGE, HT ;
SANDLER, H ;
BAXLEY, WA ;
HAWLEY, RR .
AMERICAN JOURNAL OF CARDIOLOGY, 1966, 18 (01) :10-&
[9]   STEADY-STATE FREE PRECESSION IMAGING IN THE PRESENCE OF MOTION - APPLICATION FOR IMPROVED VISUALIZATION OF THE CEREBROSPINAL-FLUID [J].
HAACKE, EM ;
WIELOPOLSKI, PA ;
TKACH, JA ;
MODIC, MT .
RADIOLOGY, 1990, 175 (02) :545-552
[10]   FUNCTIONAL-EVALUATION OF THE HEART WITH MAGNETIC-RESONANCE IMAGING [J].
HIGGINS, CB ;
HOLT, W ;
PFLUGFELDER, P ;
SECHTEM, U .