A polypyrrole-based solid-contact Pb2+-selective PVC-membrane electrode with a nanomolar detection limit

被引:115
作者
Sutter, J [1 ]
Lindner, E
Gyurcsányi, RE
Pretsch, E
机构
[1] ETH Honggerberg, Organ Chem Lab, CH-8093 Zurich, Switzerland
[2] Univ Memphis, Dept Biomed Engn, Memphis, TN 38152 USA
[3] Budapest Univ Technol & Econ, Inst Gen & Analyt Chem, H-1111 Budapest, Hungary
关键词
ion-selective electrode; solid contact; polypyrrole; lower detection limit;
D O I
10.1007/s00216-004-2737-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ion-selective electrodes (ISE) based on conventional plasticized PVC membranes with solid inner contact (SC) have so far had unsatisfactory lower detection limits. Here it is shown that electropolymerization of pyrrole in the presence of potassium hexacyanoferrate(II)(III) on Pt results in adequate inner contact for SC-ISE. The nanomolar lower detection limit achieved with the Pb2+-selective PVC membranes investigated is comparable with values obtained with optimized internal solutions of liquid-contact ISE.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 48 条
  • [41] Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes
    Schnierle, P
    Kappes, T
    Hauser, PC
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (17) : 3585 - 3589
  • [42] All-solid-state chloride sensors with poly(3-octylthiopene) matrix and trihexadecylmethylammonium chlorides as an ion exchanger salt
    Sjöberg-Eerola, P
    Bobacka, J
    Sokalski, T
    Mieczkowski, J
    Ivaska, A
    Lewenstam, A
    [J]. ELECTROANALYSIS, 2004, 16 (05) : 379 - 385
  • [43] Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes
    Sokalski, T
    Zwickl, T
    Bakker, E
    Pretsch, E
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (06) : 1204 - 1209
  • [44] Lowering the detection limit of solvent polymeric ion-selective membrane electrodes. 2. Influence of composition of sample and internal electrolyte solution
    Sokalski, T
    Ceresa, A
    Fibbioli, M
    Zwickl, T
    Bakker, E
    Pretsch, E
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (06) : 1210 - 1214
  • [45] Large improvement of the lower detection limit of ion-selective polymer membrane electrodes
    Sokalski, T
    Ceresa, A
    Zwickl, T
    Pretsch, E
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (46) : 11347 - 11348
  • [46] All-solid-state carbonate-selective electrode based on a molecular tweezer-type neutral carrier with solvent-soluble conducting polymer solid contact
    Song, FY
    Ha, JH
    Park, B
    Kwak, TH
    Kim, IT
    Nam, H
    Cha, GS
    [J]. TALANTA, 2002, 57 (02) : 263 - 270
  • [47] SUTTER J, 2004, IN PRESS ANAL CHIM A
  • [48] Influence of oxygen and carbon dioxide on the electrochemical stability of poly(3,4-ethylenedioxythiophene) used as ion-to-electron transducer in all-solid-state ion-selective electrodes
    Vázquez, M
    Bobacka, J
    Ivaska, A
    Lewenstam, A
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (01) : 7 - 13