The X-ray response of TlBr

被引:28
作者
Owens, A
Bavdaz, M
Brammertz, G
Gostilo, V
Graafsma, H
Kozorezov, A
Krumrey, M
Lisjutin, I
Peacock, A
Puig, A
Sipila, H
Zatoloka, S
机构
[1] ESA, ESTEC, Sci Payloads & Adv Concepts Off, NL-2200 AG Noordwijk, Netherlands
[2] Balt Sci Instruments, LV-1005 Riga, Latvia
[3] European Synchrotron Radiat Facil, Expt Div, F-38043 Grenoble, France
[4] Univ Lancaster, Dept Phys, Lancaster, England
[5] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[6] Metorex Int Oy, FIN-02201 Espoo, Finland
关键词
compound semiconductors; TlBr; X-rays;
D O I
10.1016/S0168-9002(02)01805-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present the results of a series of X-ray measurements on several prototype T1Br detectors. The devices were fabricated from mono-crystalline material and were typically of size 2.7 x 2.7 x 0.8 mm(3). The material is extremely pure, having impurity concentrations <100 ppm. The measured electron and hole mobility-lifetime products were found to be 3 x 10(-4) and 1 x 10(-5) cm(2) V-1, respectively, which are about an order of magnitude higher than previously reported values. Three detectors were fabricated and extensively tested over the energy range 2.3-100 keV at three synchrotron radiation facilities: the Physikalisch-Technische Bundesanstalt (PTB) laboratory at the Berliner Elektronenspeicherring fur Synchrotronstrahlung (BESSY II), the European Synchrotron Radiation Research Facility (ESRF) and the Hamburger Synchrotron-strahlungslabor (HASYLAB) radiation facility. Room temperature energy resolutions under full-area illumination of 1.8 and 3.3 keV FWHM have been achieved at 5.9 and 59.95 keV, respectively. At reduced detector temperatures of -30degreesC, these fall to 800 eV and 2.6 keV FWHM, respectively. Under monochromatic pencil beam illumination, the measured energy resolutions at 6 and 60 keV were 664 eV and similar to3 keV FWHM at the same temperature. For energies <20 keV, the measured spectra display symmetric photopeaks. However, the peaks become increasingly tailed at higher energies. At the highest energies, the energy-losses due to the electrons and holes are clearly separated. Whilst the detectors gave reproducible results over 12 months of operation, it was observed that for synchrotron beam measurements above similar to45 keV, they were unstable, showing rate dependent gain shifts and polarization effects. These were not observed at lower energies. The spatial uniformity of the detectors was measured using a 50 x 50 mum(2), 12 keV mono-energetic X-ray beam, raster scanned over the forward active area. Whilst two detectors were spatially uniform to a level commensurate with statistics, the third was not. In all cases, evidence was found for charge collection problems caused by field fringing. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:370 / 380
页数:11
相关论文
共 14 条
[1]   Future space applications of compound semiconductor X-ray detectors [J].
Bavdaz, M ;
Peacock, A ;
Owens, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :123-131
[2]   Comments on Ramo's theorem [J].
Hamel, LA ;
Julien, M .
HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS III, 2001, 4507 :255-263
[3]   For the mechanism of the photoelectric primary current in insulating crystals. [J].
Hecht, Karl .
ZEITSCHRIFT FUR PHYSIK, 1932, 77 (3-4) :235-245
[4]   Improved spectrometric characteristics of thallium bromide nuclear radiation detectors [J].
Hitomi, K ;
Murayama, T ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :372-378
[5]   Recent progress in thallium bromide detectors for X- and γ-ray spectroscopy [J].
Hitomi, K ;
Muroi, O ;
Matsumoto, M ;
Hirabuki, R ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :365-369
[6]   Room temperature X- and gamma-ray detectors using thallium bromide crystals [J].
Hitomi, K ;
Muroi, O ;
Shoji, T ;
Suehiro, T ;
Hiratate, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :160-164
[7]  
HOFSTADTER R, 1949, PHYS REV, V75, P1120
[8]  
JAZURRAHMAN I, 1987, NUCL INSTRUM METH A, V261, P427, DOI 10.1016/0168-9002(87)90350-0
[9]   High-accuracy detector calibration at the PTB four-crystal monochromator beamline [J].
Krumrey, M ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :1175-1178
[10]  
MCGREGOR DS, 1995, SEMICONDUCTORS ROOM, P384