Amperometric Immunosensor for Carcinoembryonic Antigen in Colon Cancer Samples Based on Monolayers of Dendritic Bipodal Scaffolds

被引:88
作者
Laboria, Noemi [1 ]
Fragoso, Alex [1 ]
Kemmner, Wolfgang [2 ]
Latta, Daniel [3 ]
Nilsson, Olle [4 ]
Luz Botero, Mary [1 ]
Drese, Klaus [3 ]
O'Sullivan, Ciara K. [1 ,5 ]
机构
[1] Univ Rovira & Virgili, Dept Engn Quim, Nanobiotechnol & Bioanal Grp, Tarragona 43007, Spain
[2] Charite, Res Grp Surg Oncol, D-13125 Berlin, Germany
[3] Inst Mikrotech Mainz GmbH, D-55129 Mainz, Germany
[4] Fujirebio Diagnost AB, S-41455 Gothenburg, Sweden
[5] Inst Catalana Recerca & Estudis Avancats, Barcelona 08010, Spain
关键词
SELF-ASSEMBLED MONOLAYERS; DISEASE TOXIC GLIADIN; TUMOR-MARKERS; ELECTROCHEMICAL IMMUNOSENSOR; BREAST-CANCER; GOLD; CEA; ANTIBODY; IMMUNOASSAY; SERUM;
D O I
10.1021/ac902162e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection of proteins that signal the presence or recurrence of cancer is a powerful therapeutic tool for effective early diagnosis and treatment. Carcinoembryonic antigen (CEA) has been extensively studied as a tumor marker in clinical diagnosis. We report oil the development of ail amperometric biosensor for the detection of CEA based oil the immobilization of anti-CEA monoclonal antibody on a novel class of bipodal thiolated self-assembled monolayers containing reactive N-hydroxysuccinimide (NHS) ester end groups. The current variations showed a linear relationship with the concentration of CEA over the range of 0-200 ng/mL with a sensitivity of 3.8 nA.mL.ng(-1) and a detection limit of 0.2 ng/mL, which is well below the commonly accepted concentration threshold (5 ng/mL) used in clinical diagnosis. Real time and accelerated stability studies of the reporter antibody under various storage conditions demonstrated that the enzymatic activity and antibody affinity of the conjugate is retained for long periods of time in commercial stabilizing buffers such as StabilGuard Biomolecule Stabilizer, and a prediction of the stability trends was carried out using the kinetic and thermodynamic parameters obtained from the Arrhenius equation. The developed immunosensor as well as a commercially available enzyme-linked immunosorbent assay (ELISA) kit were successfully applied to the detection of CEA in serum samples obtained from colon cancer patients, and an excellent correlation of the levels of CEA measured was obtained. Ongoing work is looking at the incorporation of the developed biosensor into a platform for multiplexed simultaneous detection of several breast cancer related biomarkers
引用
收藏
页码:1712 / 1719
页数:8
相关论文
共 39 条
[11]   Electron permeable self-assembled monolayers of dithiolated aromatic scaffolds on gold for biosensor applications [J].
Fragoso, Alex ;
Laboria, Noemi ;
Latta, Daniel ;
O'Sullivan, Ciara K. .
ANALYTICAL CHEMISTRY, 2008, 80 (07) :2556-2563
[12]   Reduced nonspecific adsorption on covalently immobilized protein surfaces using poly(ethylene oxide) containing blocking agents [J].
Frederix, F ;
Bonroy, K ;
Reekmans, G ;
Laureyn, W ;
Campitelli, A ;
Abramov, MA ;
Dehaen, W ;
Maes, G .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 58 (01) :67-74
[13]   The application of alkanethiol self-assembled monolayers to enzyme electrodes [J].
Gooding, JJ ;
Hibbert, DB .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (08) :525-533
[14]   CEA and CA 549 in serum and pleural fluid of patients with pleural effusion [J].
Hernández, L ;
Espasa, A ;
Fernández, C ;
Candela, A ;
Martín, C ;
Romero, S .
LUNG CANCER, 2002, 36 (01) :83-89
[15]   Development of an immunosensor for the determination of allergy antibody (IgE) in blood samples [J].
Kreuzer, MP ;
O'Sullivan, CK ;
Pravda, M ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 2001, 442 (01) :45-53
[16]   A reusable capacitive immunosensor for carcinoembryonic antigen (CEA) detection using thiourea modified gold electrode [J].
Limbut, W ;
Kanatharana, P ;
Mattiasson, B ;
Asawatreratanakul, P ;
Thavarungkul, P .
ANALYTICA CHIMICA ACTA, 2006, 561 (1-2) :55-61
[17]  
MacDonald JS, 1999, SEMIN ONCOL, V26, P556
[18]   c-erbB-2 oncoprotein, CEA, and CA15.3 in patients with breast cancer:: prognostic value [J].
Molina, R ;
Jo, J ;
Filella, X ;
Zanon, G ;
Pahisa, J ;
Muñoz, M ;
Farrus, B ;
Latre, ML ;
Escriche, C ;
Estape, J ;
Ballesta, AM .
BREAST CANCER RESEARCH AND TREATMENT, 1998, 51 (02) :109-119
[19]  
Mujagic Zlata, 2004, Med Arh, V58, P23
[20]   Electrochemical Immunosensor for Detection of Celiac Disease Toxic Gliadin in Foodstuff [J].
Nassef, Hossam M. ;
Redondo, M. Carmen Bermudo ;
Ciclitira, Paul J. ;
Ellis, H. Julia ;
Fragoso, Alex ;
O'Sullivan, Ciara K. .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9265-9271