Multiresponse optimization and parallel factor analysis, useful tools in the determination of estrogens by gas chromatography-mass spectrometry

被引:37
作者
Arroyo, David
Ortiz, M. Cruz
Sarabia, Luis A.
机构
[1] Univ Burgos, Fac Sci, Dept Chem, Burgos 09001, Spain
[2] Univ Burgos, Fac Sci, Dept Math & Comp Sci, Burgos 09001, Spain
关键词
estrogens; GC/MS; doehlert design; desirability; PARAFAC; PARAFAC2; decision limit; CC alpha; capability of detection; CC beta; trueness; precision;
D O I
10.1016/j.chroma.2007.04.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports an experimental design optimization of a recently proposed silylation procedure that avoids the introduction of false positives and false negatives in the simultaneous determination of steroid hormone estrone (EI) and 17-alpha-ethinylestradiol (EE2) by gas chromatography-mass spectrometry (GC/MS). The figures of merit for several calibration procedures were evaluated under optimum conditions in the silylation step. Internal standardization strategies were applied and global models were constructed by gathering signals recorded on three non-consecutive days. Three calibration models were examined: a univariate model with a sum of six monitorized ions and a three-way PARAFAC-based model (the analyte scores were standardized on the basis of the scores of the internal standard). The global PARAFAC-based calibration model showed the best performance with detection capabilities of 4.3 mu g l(-1) and 7.0 mu g l(-1) for E1 and EE2, respectively, when the probability of false positives was fixed at 1% and that of false negatives at 5%. Mean relative error in absolute terms for E1 and for EE2 was 11.1 % and 8.5%, respectively, and trueness was likewise confirmed. The proposed optimized derivatization procedure using a three-way calibration function was also applied in the determination of E1, 17-beta-estradiol (E2) and EE2 in bovine urine samples: recovery values were 68.5%, 40.4% and 43.4%, respectively, and the detection capability was 18.4, 19.3 and 18.6 mu g l(-1) when the probability of false positives was fixed at 1% and that of false negatives at 5%. Mean relative error in absolute terms for E1, E2 and EE2 was 7.4%, 9.4% and 8.6%, respectively, and trueness was likewise confirmed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:358 / 368
页数:11
相关论文
共 45 条
  • [21] Lewis G. A., 1999, PHARM EXPT DESIGN
  • [22] Multiresidue analysis of anabolic compounds in bovine hair by gas chromatography-tandem mass spectrometry
    Marcos, V
    Perogordo, E
    Espinosa, P
    de Pozuelo, MM
    Hooghuis, H
    [J]. ANALYTICA CHIMICA ACTA, 2004, 507 (02) : 219 - 227
  • [23] Myers R.H., 2002, Response Surface Methodology Process and Product Optimization Using Design Experiments, V2nd, DOI DOI 10.2307/1270613
  • [24] Determination of estrogens in river water by gas chromatography-negative-ion chemical-ionization mass spectrometry
    Nakamura, S
    Sian, TH
    Daishima, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (02) : 275 - 282
  • [25] Development and validation of an analytical method for detection of estrogens in water
    Noppe, H
    De Wasch, K
    Poelmans, S
    Van Hoof, N
    Verslycke, T
    Janssen, CR
    De Brabander, H
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (01) : 91 - 98
  • [26] Capability of detection of an analytical method evaluating false positive and false negative (ISO 11843) with partial least squares
    Ortiz, MC
    Sarabia, LA
    Herrero, A
    Sánchez, MS
    Sanz, MB
    Rueda, ME
    Giménez, D
    Meléndez, ME
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 69 (1-2) : 21 - 33
  • [27] ORTIZ MC, 2007, J CHROMATOGR A, DOI DOI 10.1016/J.CHROMA.2007.04.07
  • [28] Calibration transfer for solving the signal instability in quantitative headspace-mass spectrometry
    Pavón, JLP
    Sánchez, MD
    Pinto, CG
    Laespada, MEF
    Cordero, BM
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (22) : 6361 - 6367
  • [29] Determination of natural and synthetic estrogens in water by gas chromatography with mass spectrometric detection
    Quintana, JB
    Carpinteiro, J
    Rodríguez, I
    Lorenzo, RA
    Carro, AM
    Cela, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1024 (1-2) : 177 - 185
  • [30] DETARCHI - A PROGRAM FOR DETECTION LIMITS WITH SPECIFIED ASSURANCE PROBABILITIES AND CHARACTERISTIC CURVES OF DETECTION
    SARABIA, L
    ORTIZ, MC
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (01) : 1 - 6