Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis

被引:118
作者
Cademartiri, Filippo
Schuijf, Joanne D.
Pugliese, Francesca
Mollet, Nico R.
Jukema, J. Wouter
Maffiel, Erica
Kroft, Lucia J.
Palumbo, Alessandro
Ardissino, Diego
Serruys, Patrick W.
Krestin, Gabriel P.
Van der Wall, Ernst E.
de Feyter, Pim J.
Bax, Jeroen J.
机构
[1] Leiden Univ, Med Ctr, Dept Radiol & Cardiol, NL-2333 ZA Leiden, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Radiol & Cardiol, NL-3000 DR Rotterdam, Netherlands
[3] Univ Parma, Azienda Osped, Dept Radiol & Cardiol, I-43100 Parma, Italy
[4] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
关键词
D O I
10.1016/j.jacc.2007.02.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study sought to evaluate the diagnostic accuracy of 64-slice multislice computed tomography (MSCT) coronary angiography in the follow-up of patients with previous coronary stent implantation. Background Recent investigations have shown increased image quality and diagnostic accuracy for noninvasive coronary angiography with 64-slice MSCT as compared with previous-generation MSCT scanners, but data on the evaluation of coronary stents are scarce. Methods In 182 patients (152 [84%] male, ages 58 +/- 11 years) with previous stent (>= 2.5 mm diameter) implantation (n = 192), 64-slice MSCT angiography using either a Sensation 64 (Siemens, Forchheim, Germany) or Aquilion 64 (Toshiba, Otawara, Japan) was performed. At each center, coronary stents were evaluated by 2 experienced observers and evaluated for the presence of significant (>= 50%) in-stent restenosis. Quantitative coronary angiography served as the standard of reference. Results A total of 14 (7.3%) stented segments were excluded because of poor image quality. In the interpretable stents, 20 of the 178 (11.2%) evaluated stents were significantly diseased, of which 19 were correctly detected by 64-slice MSCT. Accordingly, sensitivity, specificity, and positive and negative predictive value to identify in-stent restenosis in interpretable stents were 95.0% (95% confidence interval [CI] 85% to 100%), 93.0% (95% CI 90% to 97%), 63.3% (95% CI 46% to 81%), and 99.3% (95% CI 98% to 100%), respectively. Conclusions In-stent restenosis can be evaluated with 64-slice MSCT with good diagnostic accuracy. In particular, a high negative predictive value of 99% was observed, indicating that 64-slice MSCT may be most valuable as a noninvasive method of excluding in-stent restenosis.
引用
收藏
页码:2204 / 2210
页数:7
相关论文
共 24 条
[1]   Assessment of coronary artery disease by cardiac computed tomography - A scientific statement from the American Heart Association committee on cardiovascular imaging and intervention, council on cardiovascular radiology and intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology [J].
Budoff, Matthew J. ;
Achenbach, Stephan ;
Blumenthal, Roger S. ;
Carr, J. Jeffrey ;
Goldin, Jonathan G. ;
Greenland, Philip ;
Guerci, Alan D. ;
Lima, Joao A. C. ;
Rader, Daniel J. ;
Rubin, Geoffrey D. ;
Shaw, Leslee J. ;
Wiegers, Susan E. .
CIRCULATION, 2006, 114 (16) :1761-1791
[2]   Usefulness of multislice computed tomographic coronary angiography to assess in-stent restenosis [J].
Cademartiri, F ;
Mollet, N ;
Lemos, PA ;
Pugliese, F ;
Baks, T ;
McFadden, EP ;
Krestin, GP ;
de Feyter, PJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (06) :799-802
[3]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[4]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[5]   Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography [J].
Gaspar, T ;
Halon, DA ;
Lewis, BS ;
Adawi, S ;
Schliamser, JE ;
Rubinshtein, R ;
Flugelman, MY ;
Peled, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) :1573-1579
[6]   Assessment of coronary artery stents by 16 slice computed tomography [J].
Gilard, M ;
Cornily, JC ;
Pennec, PY ;
Le Gal, G ;
Nonent, M ;
Mansourati, J ;
Blanc, JJ ;
Boschat, J .
HEART, 2006, 92 (01) :58-61
[7]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[8]   ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging - A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology [J].
Hendel, Robert C. ;
Patel, Manesh R. ;
Kramer, Christopher M. ;
Poon, Michael ;
Hendel, Robert C. ;
Brindis, Ralph G. ;
Hendel, Robert C. ;
Douglas, Pamela S. ;
Peterson, Eric D. ;
Wolk, Michael J. ;
Allen, Joseph M. ;
Patel, Manesh R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (07) :1475-1497
[9]   Multislice spiral computed tomography for the detection of coronary stent restenosis and patency [J].
Krüger, S ;
Mahnken, AH ;
Sinha, AM ;
Borghans, A ;
Dedden, K ;
Hoffmann, R ;
Hanrath, P .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 89 (2-3) :167-172
[10]   Accuracy of MSCT coronary angiography with 64-slice technology:: first experience [J].
Leschka, S ;
Alkadhi, H ;
Plass, A ;
Desbiolles, L ;
Grünenfelder, J ;
Marincek, B ;
Wildermuth, S .
EUROPEAN HEART JOURNAL, 2005, 26 (15) :1482-1487