Flexible manipulation of microfluids using optically regulated adsorption/desorption of hydrophobic materials

被引:31
作者
Nagai, Hidenori
Irie, Takashi
Takahashi, Junko
Wakida, Shin-ichi
机构
[1] Natl Inst Adv Ind Sci & Technol, Human Stress Signal Res Ctr, Ikeda, Osaka 5638577, Japan
[2] Natl Inst Adv Ind Sci & Technol, Technol Informat Dept, Tsukuba, Ibaraki 3058568, Japan
关键词
microvalve; photodesorption; super-hydrophilic; photocatalysis; titanium dioxide; surface wettability;
D O I
10.1016/j.bios.2006.08.037
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To realize highly integrated micro total analysis systems (mu TAS), a simply controlled miniaturized valve should be utilized on microfluidic device. In this paper, we describe the application of photo-induced super-hydrophilicity of titanium dioxide (TiO2) to microfluidic manipulation. In addition, we found a new phenomenon for reversibly converting the surface wettability using a polydimethylsiloxane (PDMS) matrix and the photocatalytic properties of TiO2. While PDMS polymer was irradiated with UV, it was confirmed that hydrophobic material was released from the polymer to air. Several prepolymers were identified as the hydrophobic material with a gas chromatograph and mass spectrometer (GUMS). Here, we successfully demonstrated the flexible manipulation of microfluid in a branched microchannel using the reversible wettability as micro opto-switching valve (MOS/V). The simultaneous control of MOS/Vs was also demonstrated on a 256-MOS/V integrated disk. The MOS/V promises to be one of the most effective flow switching valves for advanced applications in highly integrated micro/nano fluidics. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1968 / 1973
页数:6
相关论文
共 23 条
[11]   Effect of repeated photo-illumination on the wettability conversion of titanium dioxide [J].
Nakajima, A ;
Koizumi, S ;
Watanabe, T ;
Hashimoto, K .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2001, 146 (1-2) :129-132
[12]   Photoinduced elimination of oxygen at Ag(110)-p(2 x 1)-O: The role of surface carbon species [J].
Ohta, M ;
Watanabe, K ;
Matsumoto, Y .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (34) :8170-8177
[13]   Sample flow switching techniques on microfluidic chips [J].
Pan, YJ ;
Lin, JJ ;
Luo, WJ ;
Yang, RJ .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1644-1648
[14]   Polymer micro valve with a hydraulic piezo-drive fabricated by the AMANDA process [J].
Rogge, T ;
Rummler, Z ;
Schomburg, WK .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) :206-212
[15]   Preparation of poly(N-isopropylacrylamide)-modified glass surface for flow control in microfluidics [J].
Saitoh, T ;
Suzuki, Y ;
Hiraide, M .
ANALYTICAL SCIENCES, 2002, 18 (02) :203-205
[16]   Integration of an immunosorbent assay system: Analysis of secretory human immunoglobulin A on polystyrene beads in a microchip [J].
Sato, K ;
Tokeshi, M ;
Odake, T ;
Kimura, H ;
Ooi, T ;
Nakao, M ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1144-1147
[17]   Microfluidic transport based on direct electrowetting [J].
Satoh, W ;
Loughran, M ;
Suzuki, H .
JOURNAL OF APPLIED PHYSICS, 2004, 96 (01) :835-841
[18]   MICROFLOW DEVICES AND SYSTEMS [J].
SHOJI, S ;
ESASHI, M .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1994, 4 (04) :157-171
[19]   Microfluidic large-scale integration [J].
Thorsen, T ;
Maerkl, SJ ;
Quake, SR .
SCIENCE, 2002, 298 (5593) :580-584
[20]   Integration of a microextraction system on a glass chip:: Ion-pair solvent extraction of Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride [J].
Tokeshi, M ;
Minagawa, T ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1711-1714