Navigated cup implantation in hip arthroplasty A meta-analysis

被引:70
作者
Beckmann, Johannes [1 ]
Stengel, Dirk [2 ,3 ,4 ]
Tingart, Markus [1 ]
Goetz, Juergen [1 ]
Grifka, Joachim [1 ]
Luering, Christian [1 ]
机构
[1] Univ Regensburg, Dept Orthoped Surg, Bad Abbach, Germany
[2] Ernst Moritz Arndt Univ Greifswald, D-17487 Greifswald, Germany
[3] Unfallkrankenhaus Berlin, Dept Trauma F, Berlin, Germany
[4] Unfallkrankenhaus Berlin, Dept Orthopaed Surg, Berlin, Germany
关键词
ACETABULAR COMPONENT ORIENTATION; ASSISTED ORTHOPEDIC-SURGERY; CT-BASED MEASUREMENT; COMPUTER NAVIGATION; PLAIN RADIOGRAPHS; SPINE SURGERY; FREE-HAND; DISLOCATION; PLACEMENT; REPLACEMENT;
D O I
10.3109/17453670903350073
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background and purpose Many studies have suggested that navigation-based implantation can improve cup positioning in total hip arthroplasty (THA). We conducted a systematic review and meta-analysis to compile the best available evidence, and to overcome potential shortcomings because of small sample sizes in individual studies. Methods The search strategy covered the major medical databases from January 1976 through August 2007, as well as various publishers' databases. The internal validity of individual studies was evaluated independently by 3 reviewers. We used random-effects modeling to obtain mean differences in cup angulation and relative risk (RR) of cup positioning outside Lewinnek's safe zone. Results Of 363 citations originally identified, 5 trials of moderate methodology enrolling a total of 400 patients were included in the analysis. Mean cup inclination and anteversion were not statistically significantly different between the conventional groups and the navigated groups. Navigation reduced the variability in cup positioning and the risk of placing the acetabular component beyond the safe zone (RR = 0.21, CI: 0.13-0.32). Interpretation Based on the current literature, navigation is a reliable tool to optimize cup placement, and to minimize outliers. However, long-term outcomes and cost utility analyses are needed before conclusive statements can be drawn about the value of routine navigation in THA.
引用
收藏
页码:538 / 544
页数:7
相关论文
共 62 条
[41]
Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs [J].
Pradhan, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (03) :431-435
[42]
Richolt Jens A, 2005, Comput Aided Surg, V10, P87, DOI 10.3109/10929080500229447
[43]
The accuracy of free-hand cup positioning -: a CT based measurement of cup placement in 105 total hip arthroplasties [J].
Saxler, G ;
Marx, A ;
Vandevelde, D ;
Langlotz, U ;
Tannast, M ;
Wiese, M ;
Michaelis, U ;
Kemper, G ;
Grützner, PA ;
Steffen, R ;
von Knoch, M ;
Holland-Letz, T ;
Bernsmann, K .
INTERNATIONAL ORTHOPAEDICS, 2004, 28 (04) :198-201
[44]
Comparison of free-hand and computer assisted cup placement in total hip arthroplasty -: a multi-center study [J].
Saxler, G ;
Marx, A ;
Vandevelde, D ;
Langlotz, U ;
Tannast, M ;
Wiese, M ;
Michaelis, U ;
Kemper, G ;
Grützner, PA ;
Steffen, R ;
von Knoch, M ;
Holland-Letz, T ;
Bernsmann, K .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (03) :286-291
[45]
Computer-assisted orthopaedic surgery: Do we need CAOS? [J].
Sikorski, JM ;
Chauhan, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (03) :319-323
[46]
Dislocation after total hip arthroplasty [J].
Soong, M ;
Rubash, HE ;
Macaulay, W .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (05) :314-321
[47]
Computer navigation of the acetabular component - A cadaver reliability study [J].
Spencer, J. M. F. ;
Day, R. E. ;
Sloan, K. E. ;
Beaver, R. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07) :972-975
[48]
Stiehl James B, 2005, Comput Aided Surg, V10, P321, DOI 10.3109/10929080500379499
[49]
Stindel E, 2007, REV CHIR ORTHOP REPA, V93, p2S11
[50]
Stipcak V, 2004, Acta Chir Orthop Traumatol Cech, V71, P288