AC frequency characteristics of coplanar impedance sensors as design parameters

被引:86
作者
Hong, J
Yoon, DS
Kim, SK
Kim, TS
Kim, S
Pak, EY
No, K
机构
[1] Korea Adv Inst Sci & Technol, Dept Mat Sci & Engn, Taejon 305701, South Korea
[2] Korea Inst Sci & Technol, Microsyst Res Ctr, Bio MEMS, Seoul 130650, South Korea
[3] Samsung Adv Inst Technol, Digital Bio Lab, BioMEMS, Suwon, South Korea
关键词
D O I
10.1039/b410325d
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Glass-based microchannel chips were fabricated using photolithographic technology, and Pt thin-film microelectrodes, as coplanar impedance sensors, were integrated on them. Longitudinal design parameters, such as interelectrode spacing and electrode width, of coplanar impedance sensors were changed to determine AC frequency characteristics as design parameters. Through developing total impedance equations and modeling equivalent circuits, the dominant components in each frequency region were illustrated for coplanar impedance sensors and the measured results were compared with fitted values. As the ionic concentration increased, the value of the frequency-independent region decreased and cut-off frequencies increased. As the interelectrode spacing increased, cut-off frequencies decreased and total impedance increased. However, the width of each frequency-independent region was similar. As the electrode area increased, f(low) decreased but f(high) was fixed. We think that the decrease in R-Sol dominated over the influence of other components, which resulted in heightening f(low) and f(hig)h. The interelectrode spacing is a more significant parameter than the electrode area in the frequency characteristics of coplanar sensors. The deviation of experimentally obtained results from theoretically predicted values may result from the fringing effect of coplanar electrode structure and parasitic capacitance due to dielectric substrates. We suggest the guidelines of dominant components for sensing as design parameters.
引用
收藏
页码:270 / 279
页数:10
相关论文
共 48 条
[41]   ON THE MECHANISM OF DIELECTRIC-RELAXATION IN AQUEOUS DNA SOLUTIONS [J].
SAIF, B ;
MOHR, RK ;
MONTROSE, CJ ;
LITOVITZ, TA .
BIOPOLYMERS, 1991, 31 (10) :1171-1180
[42]   Capacitive microsensors for biochemical sensing based on porous silicon technology [J].
Schöning, MJ ;
Kurowski, A ;
Thust, M ;
Kordos, P ;
Schultze, JW ;
Lüth, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 64 (1-3) :59-64
[43]   Recent developments in detection methods for microfabricated analytical devices [J].
Schwarz, MA ;
Hauser, PC .
LAB ON A CHIP, 2001, 1 (01) :1-6
[44]   Method for fabrication of microfluidic systems in glass [J].
Stjernstrom, M ;
Roeraade, J .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1998, 8 (01) :33-38
[45]   Optimization of an electrolyte conductivity detector for measuring low ion concentrations [J].
Timmer, B ;
Sparreboom, W ;
Olthuis, W ;
Bergveld, P ;
van den Berg, A .
LAB ON A CHIP, 2002, 2 (02) :121-124
[46]  
Wang J, 1999, ANAL CHEM, V71, p328R
[47]   Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium [J].
Yang, LJ ;
Li, YB ;
Griffis, CL ;
Johnson, MG .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1139-1147
[48]   Capacitively coupled contactless conductivity detection in capillary electrophoresis [J].
Zemann, AJ .
ELECTROPHORESIS, 2003, 24 (12-13) :2125-2137