In vivo, thyroid and lens surface exposure with spiral and conventional computed tomography in dental implant radiography

被引:15
作者
Bianchi, J
Goggins, W
Rudolph, M
机构
[1] Univ Chile, Fac Dent, Maxillofacial Radiol Dept, Santiago, Chile
[2] Harvard Univ, Sch Dent Med, Cambridge, MA 02138 USA
[3] Harvard Univ, Sch Publ Hlth, Cambridge, MA 02138 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 2000年 / 90卷 / 02期
关键词
D O I
10.1067/moe.2000.107354
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To compare the surface dose exposure to the lens of the eye and the thyroid gland received by patients undergoing spiral and conventional computed tomography (CT) examinations during dental implant pretreatment evaluation in critical radiosensitive structures of the maxillofacial region. Study design, Two groups of 10 patients each had a dental implant CT examination performed, with 5 patients in each group having maxillary and 5 having mandibular examinations. One group was examined with conventional CT and the other with spiral CT. Seven examination parameters were standardized to both types of examinations. Lithium fluoride thermoluminescent dosimeters were placed over the thyroid gland, lateral orbit, and infraorbital foramen of each patient to measure the surface dose. The Wilcoxon rank sum test was used to compare doses, with statistical significance set at P < .05. Results, For the maxillary examination, there was a 57.4% reduction in the surface dose at the lateral orbit, 47% at the infraorbital foramen, and 60.8% at the thyroid when spiral CT was used instead of conventional CT with the same parameters. Similarly, for the mandibular examination, there was a 57.4% reduction at the lateral orbit, 60% reduction at the infraorbital foramen, and 70.9% at the thyroid. All the dose reductions were statistically significant at P < .05. Conclusion. The use of spiral CT for preimplant evaluation reduces the surface absorbed dose in certain critical structures of the maxillofacial region compared with conventional CT.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 15 条
[1]   Linear tomography's clinical accuracy and validity for presurgical dental implant analysis [J].
Butterfield, KJ ;
Dagenais, M ;
Clokie, C .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1997, 84 (02) :203-209
[2]  
CLARK D E, 1990, Journal of Oral Implantology, V16, P156
[3]   Hypothetical mortality risk associated with spiral computed tomography of the maxilla and mandible [J].
Dula, K ;
Mini, R ;
vanderStelt, PF ;
Lambrecht, JT ;
Schneeberger, P ;
Buser, D .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1996, 104 (5-6) :503-510
[4]   The use of tomography for dental implant planning [J].
Ekestubbe, A ;
Grondahl, K ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1997, 26 (04) :206-213
[5]   Dose distribution in conventional CT and spiral CT and the question of dose reduction in spiral CT [J].
Hidajat, N ;
Schroder, RJ ;
Vogl, T ;
Maurer, J ;
Steger, W ;
Felix, R .
RADIOLOGE, 1998, 38 (05) :438-443
[6]   Radiation exposure in spiral computed tomography -: Dose distribution and dose reduction [J].
Hidajat, N ;
Mäurer, J ;
Schröder, RJ ;
Wolf, M ;
Vogl, T ;
Felix, R .
INVESTIGATIVE RADIOLOGY, 1999, 34 (01) :51-57
[7]  
MCGHEE PL, 1994, CAN ASSOC RADIOL J, V45, P124
[8]  
MORLEY DR, 1985, CANAD DENT ASS J, V51, P683
[9]  
NADAS S, 1994, J RADIOL, V75, P217
[10]   Use of spiral computed tomography for multiplanar dental reconstruction [J].
Preda, L ;
DiMaggio, EM ;
Dore, R ;
LaFianza, A ;
Solcia, M ;
Schifino, MR ;
Campani, R ;
Preda, EG .
DENTOMAXILLOFACIAL RADIOLOGY, 1997, 26 (06) :327-331