Microcapillary reversed-displacement immunosensor for trace level detection of TNT in seawater

被引:36
作者
Charles, PT
Rangasammy, JG
Anderson, GP
Romanoski, TC
Kusterbeck, AW
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
[2] Geocenters Inc, Arlington, VA 22209 USA
关键词
TNT; 2,4,6-trinitrotoluene; immunosensor; microcapillary; fluorescence; antibody;
D O I
10.1016/j.aca.2004.08.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
reversed-displacement immunosensor to detect the explosive, 2,4,6-trinitrotoluene (TNT) using a chemically modified borosilicate glass microcapillary is described. The inner core of a glass microcapillary was modified with 3-aminopropyltriethoxysilane and functionalized with the TNT analog, trinitrobenzene sulfonic acid (TNBSA). A Cy5-labeled anti-TNT antibody was incubated within the trinitrobenzene (TNB) modified microcapillary until binding equilibrium, forming the TNB-anti-TNT antibody complex. The TNB-microcapillary was then subjected to a constant flow of buffer as samples were applied. As samples containing TNT were introduced into the microcapillary flow stream, the Cy5-labeled antibody bound to the immobilized TNB was displaced and fluorescence measured by a fluorometer. Using the microcapillary-based reversed-displacement immunosensor (MRDI) format, parts-per-trillion (pptr) detection limits for TNT in seawater (0.25 ng/mL or 250 pptr) was achieved with an analysis time under 5 min. Reported also are experimental results comparing silane deposition conditions and the effect on immunoassay performance and the comparison of fluorescence signal response with the MRDI using four different monoclonal anti-TNT antibodies. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 25 条
[11]   Electrochemical DNA biosensor for analysis of wastewater samples [J].
Lucarelli, F ;
Kicela, A ;
Palchetti, I ;
Marrazza, G ;
Mascini, M .
BIOELECTROCHEMISTRY, 2002, 58 (01) :113-118
[12]   Immunosensors for pesticide determination in natural waters [J].
Mallat, E ;
Barceló, D ;
Barzen, C ;
Gauglitz, G ;
Abuknesha, R .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (03) :124-132
[13]   Development of a monoclonal antibody based potentiometric biosensor for terbuthylazine detection [J].
Mosiello, L ;
Laconi, C ;
Del Gallo, M ;
Ercole, C ;
Lepidi, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 95 (1-3) :315-320
[14]   Amperometric TNT biosensor based on the oriented immobilization of a nitroreductase maltose binding protein fusion [J].
Naal, Z ;
Park, JH ;
Bernhard, S ;
Shapleigh, JP ;
Batt, CA ;
Abruña, HD .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :140-148
[15]   Multianalyte detection using a capillary-based flow immunosensor [J].
Narang, U ;
Gauger, PR ;
Kusterbeck, AW ;
Ligler, FS .
ANALYTICAL BIOCHEMISTRY, 1998, 255 (01) :13-19
[16]   A displacement flow immunosensor for explosive detection using microcapillaries [J].
Narang, U ;
Gauger, PR ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1997, 69 (14) :2779-2785
[17]   EFFECT OF ANTIBODY DENSITY ON THE DISPLACEMENT KINETICS OF A FLOW IMMUNOASSAY [J].
RABBANY, SY ;
KUSTERBECK, AW ;
BREDEHORST, R ;
LIGLER, FS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 168 (02) :227-234
[18]   Assessment of heterogeneity in antibody-antigen displacement reactions [J].
Rabbany, SY ;
Piervincenzi, R ;
Judd, L ;
Kusterbeck, AW ;
Bredehorst, R ;
Hakansson, K ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :175-182
[19]   Ascorbate oxidase based amperometric biosensor for organophosphorous pesticide monitoring [J].
Rekha, K ;
Gouda, MD ;
Thakur, MS ;
Karanth, NG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10) :499-502
[20]   Demonstration of four immunoassay formats using the array biosensor [J].
Sapsford, KE ;
Charles, PT ;
Patterson, CH ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1061-1068