The square stent-based large vessel occluder:: An experimental pilot study

被引:13
作者
Pavcnik, D
Uchida, BT
Timmermans, H
Corless, CL
Loriaux, M
Keller, FS
Rösch, J
机构
[1] Oregon Hlth Sci Univ, Dotter Intervent Inst, Portland, OR 97201 USA
[2] Oregon Hlth Sci Univ, Dept Pathol, Portland, OR 97201 USA
关键词
stents and prostheses; interventional procedures; experimental; embolization;
D O I
10.1016/S1051-0443(07)61369-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The purpose of this study is in vitro and in vivo experimental evaluation of a square stent-based vascular occlusion device for large vessels, MATERIALS AND METHODS: Square stent-based large vessel occluders (LVO) 5 mm-50 mm in size were constructed from stainless-steel square stents covered by porcine small intestine submucosa (SIS), The LVOs with two back-side barbs were delivered through a guiding catheter, The LVOs with two back-side barbs and two frontal barbs were front-loaded and delivered coaxially, A pusher with a retention mechanism at its end was used for deployment, In vitro testing for competency was performed with use of a flow model with pressure increases, In an experimental pilot study in seven pigs and five dogs, 16 LVOs were placed into the aorta (n = 4), common iliac artery (n = 2), pulmonary artery (n = 4), and medial sacral artery (n = 6), Four animals received two LVOs in different locations, Angiography was performed before and after placement of each LVO, Animals were followed for as long as 3 months with use of angiography and were then killed for gross and histologic evaluation, RESULTS: In vitro LVOs with two and four barbs were easily collapsed and pushed through or front-loaded into guiding catheters (6-F for a 5-mm occluder, 10-F for a 50-mm occluder). A 20-mm LVO adapted to tubular structures 10-15 mm in diameter, forming polygons 17-18.5 mm in length, In the flow model, LVOs endured pressure increases to 300 mm Hg, In vivo, the LVOs self-expanded and adapted to the vessel without migration in all cases, The locking pusher allowed precise LVO placement and engagement of its barbs into the vessel wall before complete deployment, preventing dislodgment by blood flow, Complete arterial occlusion occurred within 10-20 minutes and arteries remained occluded until the animal was killed in all cases, After 2 months, histologic evaluation revealed replacement of SIS by host tissue and its remodeling with variable fibrocytes, fibroblasts, and some inflammatory cells, Complete endothelialization was seen on both sides of the LVO, CONCLUSION: The SIS LVO is effective and reliable for acute and chronic occlusion in a high flow model in an experimental animal.
引用
收藏
页码:1227 / 1234
页数:8
相关论文
共 17 条
[1]  
AIKEN SW, 1994, VET COMP ORTHOPAED, V7, P124
[2]   ELASTIC CHARACTERISTICS OF THE SELF-EXPANDING METALLIC STENTS [J].
FALLONE, BG ;
WALLACE, S ;
GIANTURCO, C .
INVESTIGATIVE RADIOLOGY, 1988, 23 (05) :370-376
[3]   MECHANICAL-PROPERTIES OF XENOGENEIC SMALL-INTESTINAL SUBMUCOSA WHEN USED AS AN AORTIC GRAFT IN THE DOG [J].
HILES, MC ;
BADYLAK, SF ;
LANTZ, GC ;
KOKINI, K ;
GEDDES, LA ;
MORFF, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (07) :883-891
[4]   Use of a self-expanding vascular occluder for embolization during endovascular aortic aneurysm repair [J].
Kato, N ;
Semba, CP ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (01) :27-33
[5]   BIOCOMPATIBILITY OF SMALL-INTESTINAL SUBMUCOSA IN URINARY-TRACT AS AUGMENTATION CYSTOPLASTY GRAFT AND INJECTABLE SUSPENSION [J].
KNAPP, PM ;
LINGEMAN, JE ;
SIEGEL, YI ;
BADYLAK, SF ;
DEMETER, RJ .
JOURNAL OF ENDOUROLOGY, 1994, 8 (02) :125-130
[6]   Preliminary results with a new vascular basket occluder in swine [J].
Kónya, A ;
Wright, KC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (08) :1043-1049
[7]  
Lantz G C, 1993, J Invest Surg, V6, P297, DOI 10.3109/08941939309141619
[8]  
MCGEE P, 1998, ORTHOPEDICS TODAY, V18, P43
[9]   VASCULAR OCCLUSION WITH A BALLOON-EXPANDABLE STENT OCCLUDER [J].
MOSS, JG ;
LABORDE, JC ;
CLEM, MC ;
RIVERA, FJ ;
ENCARNACION, CE ;
MEYER, KB ;
PALMAZ, JC .
RADIOLOGY, 1994, 191 (02) :483-486
[10]   EVALUATION OF A NEW VASCULAR OCCLUSION DEVICE [J].
NAZARIAN, GK ;
QIAN, Z ;
VLODAVER, Z ;
POZZA, CH ;
CASTANEDAZUNIGA, WR ;
HUNTER, DW ;
AMPLATZ, K .
INVESTIGATIVE RADIOLOGY, 1993, 28 (12) :1165-1169