Biosensor based on polyaniline-Prussian Blue/multi-walled carbon nanotubes hybrid composites

被引:120
作者
Zou, Yongjin
Sun, Li-Xian [1 ]
Xu, Fen
机构
[1] Chinese Acad Sci, Mat & Thermochem Lab, Dalian 116023, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
glucose biosensor; carbon nanotubes; polyaniline; Prussian blue; hybrid composites;
D O I
10.1016/j.bios.2006.10.035
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this work, a novel route for fabrication polyaniline (PANI)-Prussian Blue (PB) hybrid composites is proposed by the spontaneous redox reaction in the FeCl3-K-3[Fe(CN)(6)] and the aniline solution. With the introduction of multi-walled carbon nanotubes (MWNTs), the PANI-PB/MWNTs system shows synergy between the PANI-PB and MWNTs which amplified the H2O2 sensitivity greatly. A linear range from 8 x 10(-8) to 1 X 10(-5) M and a high sensitivity 508.18 mu A mu M cm(2) for H2O2 detection are obtained. The composites also show good stability in neutral solution. A glucose biosensor was further constructed by immobilizing glucose oxidase (GOD) with Nation and glutaraldehyde on the electrode surface. The performance factors influencing the resulted biosensor were studied in detail. The biosensor exhibits excellent response performance to glucose with the linear range from 1 to 11 mM and a detection limit of 0.01 mM. Furthermore, the biosensor shows rapid response, high sensitivity, good reproducibility, long-term stability and freedom of interference from other co-existing electroactive species. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2669 / 2674
页数:6
相关论文
共 33 条
[11]   A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode [J].
Lim, SH ;
Wei, J ;
Lin, JY ;
Li, QT ;
KuaYou, J .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (11) :2341-2346
[12]   Al2O3 sol-gel derived amperometric biosensor for glucose [J].
Liu, ZJ ;
Liu, BH ;
Zhang, M ;
Kong, JL ;
Deng, JQ .
ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) :135-141
[13]   Glucose biosensor based on ENFET doped with SiO2 nanoparticles [J].
Luo, XL ;
Xu, JJ ;
Zhao, W ;
Chen, HY .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 97 (2-3) :249-255
[14]   Urea biosensor based on PANi(urease)-Nation®/Au composite electrode [J].
Luo, YC ;
Do, JS .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (01) :15-23
[15]   In situ FTIR studies on Prussian blue (PB)-, polyaniline (PAn)- and inner PB|outer PAn film-modified electrodes [J].
Nakayama, M ;
Iino, M ;
Ogura, K .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 440 (1-2) :125-130
[16]   Home blood glucose biosensors: a commercial perspective [J].
Newman, JD ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2435-2453
[17]   Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode [J].
Razola, SS ;
Ruiz, BL ;
Diez, NM ;
Mark, HB ;
Kauffmann, JM .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :921-928
[18]   Prussian Blue based screen printed biosensors with improved characteristics of long-term lifetime and pH stability [J].
Ricci, F ;
Amine, A ;
Palleschi, G ;
Moscone, D .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :165-174
[19]   Inert metal-modified, composite ceramic-carbon, amperometric biosensors: Renewable, controlled reactive layer [J].
Sampath, S ;
Lev, O .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2015-2021
[20]   Polyaniline-Prussian blue hybrid: synthesis and magnetic behaviour [J].
Sawant, SN ;
Bagkar, N ;
Subramanian, H ;
Yakhmi, JV .
PHILOSOPHICAL MAGAZINE, 2004, 84 (20) :2127-2138