A planar pCO2 sensor with enhanced electrochemical properties

被引:11
作者
Shin, JH [1 ]
Lee, JS [1 ]
Choi, SH [1 ]
Lee, DK [1 ]
Nam, H [1 ]
Cha, GS [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
关键词
D O I
10.1021/ac000427o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To develop planar microchemical pCO(2) sensing devices with improved electrochemical properties, we combined two advanced technologies. One is a differential sensor arrangement to simplify the microfabrication procedure by employing pH-sensitive gas-permeable membranes, and the other is the use of an enzyme (carbonic anhydrase) to shorten total measurement time by accelerating the rate of CO2 hydration. The adhesion of the polyurethane-matrix gas-permeable membrane is enhanced significantly by incorporating a silanizing reagent (silicon tetrachloride), improving the stability and extending sensor lifetime. The proposed differential pCO(2) microelectrodes exhibited significantly improved performance in their preconditioning period, response and recovery times, stability, response slope, and lifetime.
引用
收藏
页码:4468 / 4473
页数:6
相关论文
共 47 条
[21]  
Lee JS, 1999, ELECTROANAL, V11, P260, DOI 10.1002/(SICI)1521-4109(199904)11:4<260::AID-ELAN260>3.0.CO
[22]  
2-#
[23]   ION-SELECTIVE MEMBRANES WITH LOW PLASTICIZER CONTENT - ELECTROANALYTICAL CHARACTERIZATION AND BIOCOMPATIBILITY STUDIES [J].
LINDNER, E ;
COSOFRET, VV ;
UFER, S ;
BUCK, RP ;
KAO, WJ ;
NEUMAN, MR ;
ANDERSON, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (05) :591-601
[24]   POTENTIOMETRIC ION-SELECTIVE AND BIOSELECTIVE ELECTRODES BASED ON ASYMMETRIC POLYURETHANE MEMBRANES [J].
LIU, D ;
MEYERHOFF, ME ;
GOLDBERG, HD ;
BROWN, RB .
ANALYTICA CHIMICA ACTA, 1993, 274 (01) :37-46
[25]   SELECTIVITY OF THE POTENTIOMETRIC CARBON-DIOXIDE GAS-SENSING ELECTRODE [J].
LOPEZ, ME .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2360-2366
[26]   ENHANCED PERFORMANCE OF A FIBEROPTIC LUMINESCENCE CO2 SENSOR USING CARBONIC-ANHYDRASE [J].
MARAZUELA, MD ;
BONDI, MCM ;
ORELLANA, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) :126-131
[27]  
MEYERHOFF ME, 1990, CLIN CHEM, V36, P1567
[28]   INVIVO MEASUREMENT OF CARBON-DIOXIDE TENSION WITH A MINIATURE ELECTRODE [J].
OLIEVIER, CN ;
BERKENBOSCH, A ;
QUANJER, PH .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1978, 373 (03) :269-272
[29]  
OPDYCKE WN, 1986, ANAL CHEM, V58, P950, DOI 10.1021/ac00295a062
[30]   POLYMER-MEMBRANE PH ELECTRODES AS INTERNAL ELEMENTS FOR POTENTIOMETRIC GAS-SENSING SYSTEMS [J].
OPDYCKE, WN ;
PARKS, SJ ;
MEYERHOFF, ME .
ANALYTICA CHIMICA ACTA, 1983, 155 (DEC) :11-20