A planar pCO2 sensor with enhanced electrochemical properties

被引:11
作者
Shin, JH [1 ]
Lee, JS [1 ]
Choi, SH [1 ]
Lee, DK [1 ]
Nam, H [1 ]
Cha, GS [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
关键词
D O I
10.1021/ac000427o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To develop planar microchemical pCO(2) sensing devices with improved electrochemical properties, we combined two advanced technologies. One is a differential sensor arrangement to simplify the microfabrication procedure by employing pH-sensitive gas-permeable membranes, and the other is the use of an enzyme (carbonic anhydrase) to shorten total measurement time by accelerating the rate of CO2 hydration. The adhesion of the polyurethane-matrix gas-permeable membrane is enhanced significantly by incorporating a silanizing reagent (silicon tetrachloride), improving the stability and extending sensor lifetime. The proposed differential pCO(2) microelectrodes exhibited significantly improved performance in their preconditioning period, response and recovery times, stability, response slope, and lifetime.
引用
收藏
页码:4468 / 4473
页数:6
相关论文
共 47 条
[11]   CHEMICAL SENSORS FOR BEDSIDE MONITORING OF CRITICALLY ILL PATIENTS [J].
COLLISON, ME ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1990, 62 (07) :A425-&
[12]   EVALUATION OF A DUAL-FUNCTION PH AND PCO-2 INVIVO SENSOR [J].
COON, RL ;
LAI, NCJ ;
KAMPINE, JP .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (04) :625-629
[13]   ION-SELECTIVE MICROCHEMICAL SENSORS WITH REDUCED PRECONDITIONING TIME - MEMBRANE BIOSTABILITY STUDIES AND APPLICATIONS IN BLOOD ANALYSIS [J].
COSOFRET, VV ;
ERDOSY, M ;
LINDNER, E ;
JOHNSON, TA ;
BUCK, RP ;
KAO, WJ ;
NEUMAN, MR ;
ANDERSON, JM .
ANALYTICAL LETTERS, 1994, 27 (15) :3039-3063
[14]   Aliphatic polyurethane as a matrix for pH sensors: Effects of native sites and added proton carrier on electrical and potentiometric properties [J].
Cosofret, VV ;
Erdosy, M ;
Raleigh, JS ;
Johnson, TA ;
Neuman, MR ;
Buck, RP .
TALANTA, 1996, 43 (01) :143-151
[15]   Potentiometric pCO2 sensor using polyaniline-coated pH-sensitive electrodes [J].
Cui, G ;
Lee, JS ;
Kim, SJ ;
Nam, H ;
Cha, GS ;
Kim, HD .
ANALYST, 1998, 123 (09) :1855-1859
[16]  
DAVIS G, 1996, Patent No. 5514253
[17]   ELECTROKINETIC EFFECTS - CARBONIC-ANHYDRASE AND CO2 ELECTRODE DYNAMICS [J].
DONALDSON, TL ;
HO, SP .
CHEMICAL ENGINEERING COMMUNICATIONS, 1985, 37 (1-6) :223-231
[18]   SELECTIVITY CHARACTERISTICS OF POTENTIOMETRIC CARBON-DIOXIDE SENSORS WITH VARIOUS GAS MEMBRANE MATERIALS [J].
KOBOS, RK ;
PARKS, SJ ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1982, 54 (12) :1976-1980
[19]  
Lamba N.M.K., 1997, Polyurethanes in Biomedical Applications
[20]   Microfabricated biosensors and microanalytical systems for blood analysis [J].
Lauks, IR .
ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (05) :317-324