Development of a method for the systematic use of bilinear multivariate calibration methods for the correction of interferences in inductively coupled plasma-mass spectrometry

被引:15
作者
Rupprecht, M [1 ]
Probst, T [1 ]
机构
[1] Tech Univ Munich, Inst Radiochem, D-85747 Garching, Germany
关键词
bilinear multivariate calibration; principal component regression; partial least squares regression; interferences; ICP-MS; mass spectrometry;
D O I
10.1016/S0003-2670(97)00627-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The multivariate bilinear calibration methods Principal Component Regression (PCR) and Partial Least Squares Regression (PLS) are investigated for their capability to correct interferences in ICP-MS analysis. A universally applicable method is developed by optimizing the parameters for experimental design, for data pretreatment by internal standardisation, scaling, and mean centering, for the determination of the optimal number of latent variables, and for variable selection. Validation is performed with an artificial test system containing a wide range of representative analytes and interferences. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:205 / 225
页数:21
相关论文
共 50 条
[41]   COMPARISON OF MULTIVARIATE CALIBRATION METHODS FOR QUANTITATIVE SPECTRAL-ANALYSIS [J].
THOMAS, EV ;
HAALAND, DM .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1091-1099
[42]  
THOMAS EV, 1994, ANAL CHEM, V6, pA795
[43]   A STUDY OF INTERNAL STANDARDIZATION IN INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY [J].
THOMPSON, JJ ;
HOUK, RS .
APPLIED SPECTROSCOPY, 1987, 41 (05) :801-806
[44]   CORRECTION PROCEDURES FOR RARE-EARTH ELEMENT ANALYSES IN INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY [J].
VAUGHAN, MA ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1990, 44 (04) :587-593
[45]   DETERMINATION OF NI BY ICP-MS - CORRECTION OF CALCIUM-OXIDE AND HYDROXIDE INTERFERENCES USING PRINCIPAL COMPONENTS-ANALYSIS [J].
VAUGHAN, MA ;
TEMPLETON, DM .
APPLIED SPECTROSCOPY, 1990, 44 (10) :1685-1689
[46]  
Venth K, 1996, FRESEN J ANAL CHEM, V354, P811
[47]   REDUCTION OF MASS-DEPENDENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY BY USING FLOW-INJECTION ANALYSIS [J].
VICKERS, GH ;
ROSS, BS ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1989, 43 (08) :1330-1333
[48]   EFFECT OF ION-LENS TUNING AND FLOW-INJECTION ON NONSPECTROSCOPIC MATRIX INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
WANG, JS ;
SHEN, WL ;
SHEPPARD, BS ;
EVANS, EH ;
CARUSO, JA ;
FRICKE, FL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) :445-449
[50]   DETERMINATION OF RARE-EARTH IMPURITIES IN ULTRAPURE EUROPIUM OXIDE BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
ZHANG, SX ;
MURACHI, S ;
IMASAKA, T ;
WATANABE, M .
ANALYTICA CHIMICA ACTA, 1995, 314 (03) :193-201