The aim of this work was to quantify the ability to predict intrafraction diaphragm motion from an external respiration signal during a course of radiotherapy. The data obtained included diaphragm motion traces from 63 fluoroscopic lung procedures for 5 patients, acquired simultaneously with respiratory motion signals (an infrared camera-based system was used to track abdominal wall motion). During these sessions, the patients were asked to breathe either (i) without instruction, (ii) with audio prompting, or (iii) using visual feedback. A statistical general linear model was formulated to describe the relationship between the respiration signal and diaphragm motion over all sessions and for all breathing training types. The model parameters derived from the first session for each patient were then used to predict the diaphragm motion for subsequent sessions based on the respiration signal. Quantification of the difference between the predicted and actual motion during each session determined our ability to predict diaphragm motion during a course of radiotherapy. This measure of diaphragm motion was also used to estimate clinical target volume (CTV) to planning target volume (PTV) margins for conventional, gated, and proposed four-dimensional (4D) radiotherapy. Results from statistical analysis indicated a strong linear relationship between the respiration signal and diaphragm motion (p<0.001) over all sessions, irrespective of session number (p=0.98) and breathing training type (p=0.19). Using model parameters obtained from the first session, diaphragm motion was predicted in subsequent sessions to within 0.1 cm (1 sigma) for gated and 4D radiotherapy. Assuming a 0.4 cm setup error, superior-inferior CTV-PTV margins of 1.1 cm for conventional radiotherapy could be reduced to 0.8 cm for gated and 4D radiotherapy. The diaphragm motion is strongly correlated with the respiration signal obtained from the abdominal wall. This correlation can be used to predict diaphragm motion, based on the respiration signal, to within 0.1 cm (1 a) over a course of radiotherapy. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:505 / 513
页数:9
相关论文
共 56 条
  • [11] What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?
    Ekberg, L
    Holmberg, O
    Wittgren, L
    Bjelkengren, G
    Landberg, T
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 48 (01) : 71 - 77
  • [12] FORD E, 2002, AAPM M MONTR
  • [13] Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging
    Ford, EC
    Mageras, GS
    Yorke, E
    Rosenzweig, KE
    Wagman, R
    Ling, CC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (02): : 522 - 531
  • [14] Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
    Graham, MV
    Purdy, JA
    Emami, B
    Harms, W
    Bosch, W
    Lockett, MA
    Perez, CA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02): : 323 - 329
  • [15] Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    Hanley, J
    Debois, MM
    Mah, D
    Mageras, GS
    Raben, A
    Rosenzweig, K
    Mychalczak, B
    Schwartz, LH
    Gloeggler, PJ
    Lutz, W
    Ling, CC
    Leibel, SA
    Fuks, Z
    Kutcher, GJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03): : 603 - 611
  • [16] Radiation-induced pulmonary toxicity: A dose-volume histogram analysis in 201 patients with lung cancer
    Hernando, ML
    Marks, LB
    Bentel, GC
    Zhou, SM
    Hollis, D
    Das, SK
    Fan, M
    Munley, MT
    Shafman, TD
    Anscher, MS
    Lind, PA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (03): : 650 - 659
  • [17] ICUR, 1999, Report 62
  • [18] Potential radiotherapy improvements with respiratory gating
    Keall P.J.
    Kini V.R.
    Vedam S.S.
    Mohan R.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2002, 25 (1): : 1 - 6
  • [19] Motion adaptive x-ray therapy: a feasibility study
    Keall, PJ
    Kini, VR
    Vedam, SS
    Mohan, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01) : 1 - 10
  • [20] Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: A feasibility study
    Kim, DJW
    Murray, BR
    Halperin, R
    Roa, WHY
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (01): : 43 - 49