Corrosion resistance of titanium ion implanted AZ91 magnesium alloy

被引:60
作者
Liu, Chengiong
Xin, Yunchang
Tian, Xiubo
Zhao, J.
Chu, Paul K.
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
[2] Tsing Hua Univ, Shenzhen Grad Sch, Shenzhen 518055, Peoples R China
[3] Harbin Inst Technol, Sch Mat Sci & Engn, State Key Lab Welding Prod Technol, Harbin 15001, Peoples R China
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A | 2007年 / 25卷 / 02期
关键词
D O I
10.1116/1.2699371
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Degradable metal alloys constitute a new class of materials for load-bearing biomedical implants. Owing to their good mechanical properties and biocompatibility, magnesium alloys are promising in degradable prosthetic implants. The objective of this study is to improve the corrosion behavior of surgical AZ91 magnesium alloy by titanium ion implantation. The surface characteristics of the ion implanted layer in the magnesium alloys are examined. The authors' results disclose that an intermixed layer is produced and the surface oxidized films are mainly composed of titanium oxide with a lesser amount of magnesium oxide. X-ray photoelectron spectroscopy reveals that the oxide has three layers. The outer layer which is 10 nm thick is mainly composed of MgO and TiO2 with some Mg(OH)(2). The middle layer that is 50 nm thick comprises predominantly TiO2 and MgO with minor contributions from MgAl2O4 and TiO. The third layer from the surface is rich in metallic Mg, Ti, Al, and Ti3Al. The effects of Ti ion implantation on the corrosion resistance and electrochemical behavior of the magnesium alloys are investigated in simulated body fluids at 37 +/- 1 degrees C using electrochemical impedance spectroscopy and open circuit potential techniques. Compared to the unimplanted AZ91 alloy, titanium ion implantation significantly shifts the open circuit potential (OCP) to a more positive potential and improves the corrosion resistance at OCR This phenomenon can be ascribed to the more compact surface oxide film, enhanced reoxidation on the implanted surface, as well as the increased beta-Mg12Al17 phase. (c) 2007 American Vacuum Society.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 27 条
[1]   Improving corrosion resistance of magnesium-based alloys by surface modification with hydrogen by electrochemical ion reduction (EIR) and by plasma immersion ion implantation (PIII) [J].
Bakkar, A ;
Neubert, V .
CORROSION SCIENCE, 2005, 47 (05) :1211-1225
[2]   The corrosion of pure magnesium in aerated and deaerated sodium sulphate solutions [J].
Baril, G ;
Pébère, N .
CORROSION SCIENCE, 2001, 43 (03) :471-484
[3]   In vitro corrosion testing of PVD coatings applied to a surgical grade Co-Cr-Mo alloy [J].
Bolton, J ;
Hu, X .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (06) :567-574
[4]   Metal plasma immersion ion implantation and deposition (MPIIID): chromium on magnesium [J].
Bruckner, J ;
Gunzel, R ;
Richter, E ;
Moller, W .
SURFACE & COATINGS TECHNOLOGY, 1998, 104 :227-230
[5]  
CAO CN, 2002, INTRO ELECTROCHEMICA, P63
[6]   Principles and characteristics of a new generation plasma immersion ion implanter [J].
Chu, PK ;
Tang, BY ;
Cheng, YC ;
Ko, PK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (04) :1866-1874
[7]   Plasma immersion ion implantation - A fledgling technique for semiconductor processing [J].
Chu, PK ;
Qin, S ;
Chan, C ;
Cheung, NW ;
Larson, LA .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 1996, 17 (6-7) :207-280
[8]   Third-generation plasma immersion ion implanter for biomedical materials and research [J].
Chu, PK ;
Tang, BY ;
Wang, LP ;
Wang, XF ;
Wang, SY ;
Huang, N .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (03) :1660-1665
[9]  
Davis JR., 2003, HDB MAT MED DEVICES, V1, P22
[10]   SURFACE MODIFICATION OF AUSTENITIC STAINLESS-STEEL BY TITANIUM ION-IMPLANTATION [J].
EVANS, PJ ;
HYVARINEN, J ;
SAMANDI, M .
SURFACE & COATINGS TECHNOLOGY, 1995, 71 (02) :151-158