New method for caffeine quantification by planar chromatography coupled with electropray ionization mass spectrometry using stable isotope dilution analysis

被引:46
作者
Aranda, Mario [1 ]
Morlock, Gertrud [1 ]
机构
[1] Univ Hohenheim, Inst Food Chem, D-70599 Stuttgart, Germany
关键词
D O I
10.1002/rcm.2949
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new high-performance thin-layer chromatography/electrospray ionization mass spectrometry (HPTLC/ESI-MS) method for the quantification of caffeine in pharmaceutical and energy drink samples was developed using stable isotope dilution analysis (SIDA). After sample preparation, samples and caffeine standard were applied on silica gel 60 F(254) HPTLC plates and over-spotted with caffeine-d(3) used for correction of the plunger positioning. After chromatography, densitometric detection was performed by UV absorption at 274 nm. The bands were then eluted by means of a plunger-based extractor into the ESI interface of a single-quadrupole mass spectrometer. For quantification by MS the [M+H](+) ions of caffeine and caffeine-d(3) were recorded in the positive ion single ion monitoring (SIM) mode at m/z 195 and 198, respectively. The calibration showed a linear regression with a determination coefficient (R(2)) of 0.9998. The repeatability (RSD, n = 6) in matrix was <= +/- 3.75%. The intermediate precisions (RSD, n = 2) for two samples of different brand names were determined three times and ranged between RSD +/- 0.68% and +/- 2.64% (sample 1) and between +/- 3.44% and +/- 8.60% (sample 2). The method accuracy was evaluated by comparing the results obtained by HPTLC/SIDA-ESI-MS with those from the validated HPTLC/UV method. The results for pharmaceutical and energy drink samples were (ng/band) 99.82 +/- 3.75 and 338.09 +/- 4.87 by HPTLC/SIDA-EST-MS and 104.74 +/- 1.51 and 334.86 +/- 5.63 by HPTLC/UV. According to the F-test (homogeneity of variances) and the t-test (comparison of means) the two methods show no significant difference. The detection and quantification limits were 75 and 250 mu g L(-1) (0.75 and 2.5 ng/band), respectively, which were a factor of 13 lower than those established for HPTLC/UV. The positioning error (RSD +/- 6%) was calculated by comparing HPTLC/SIDA-ESI-MS with HPTLC/ESI-MS. However, using SIDA the positioning error was nullified. HPTLC/SIDA-ESI-MS was demonstrated to be a highly reliable method for the quantification of compounds by planar chromatography coupled online with mass spectrometry. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:1297 / 1303
页数:7
相关论文
共 37 条
[31]  
Stanley M.S., 1988, JPC-J PLANAR CHROMAT, V1, P76
[32]   GRAPHITE SURFACE ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY OF PEPTIDES AND PROTEINS FROM LIQUID SOLUTIONS [J].
SUNNER, J ;
DRATZ, E ;
CHEN, YC .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4335-4342
[33]   Mass spectrometry sampling under ambient conditions with desorption electrospray ionization [J].
Takáts, Z ;
Wiseman, JM ;
Gologan, B ;
Cooks, RG .
SCIENCE, 2004, 306 (5695) :471-473
[34]  
*US PHARM CONV, 2002, USP NF US PHARM USP, P673
[35]   Automated sampling and imaging of analytes separated on thin-layer chromatography plates using desorption electrospray ionization mass spectrometry [J].
Van Berkel, Gary J. ;
Kertesz, Vilmos .
ANALYTICAL CHEMISTRY, 2006, 78 (14) :4938-4944
[36]   Monitoring the dose of florfenicol in medicated salmon feed by planar chromatography (HPTLC) [J].
Vega, Mario H. ;
Jara, Elizabeth T. ;
Aranda, Mario B. .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2006, 19 (109) :204-207
[37]   A novel approach of combining thin-layer chromatography with surface-assisted laser desorption/ionization (SALDI) time-of-flight mass spectrometry [J].
Wu, JY ;
Chen, YC .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (01) :85-90