New method for caffeine quantification by planar chromatography coupled with electropray ionization mass spectrometry using stable isotope dilution analysis

被引:46
作者
Aranda, Mario [1 ]
Morlock, Gertrud [1 ]
机构
[1] Univ Hohenheim, Inst Food Chem, D-70599 Stuttgart, Germany
关键词
D O I
10.1002/rcm.2949
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new high-performance thin-layer chromatography/electrospray ionization mass spectrometry (HPTLC/ESI-MS) method for the quantification of caffeine in pharmaceutical and energy drink samples was developed using stable isotope dilution analysis (SIDA). After sample preparation, samples and caffeine standard were applied on silica gel 60 F(254) HPTLC plates and over-spotted with caffeine-d(3) used for correction of the plunger positioning. After chromatography, densitometric detection was performed by UV absorption at 274 nm. The bands were then eluted by means of a plunger-based extractor into the ESI interface of a single-quadrupole mass spectrometer. For quantification by MS the [M+H](+) ions of caffeine and caffeine-d(3) were recorded in the positive ion single ion monitoring (SIM) mode at m/z 195 and 198, respectively. The calibration showed a linear regression with a determination coefficient (R(2)) of 0.9998. The repeatability (RSD, n = 6) in matrix was <= +/- 3.75%. The intermediate precisions (RSD, n = 2) for two samples of different brand names were determined three times and ranged between RSD +/- 0.68% and +/- 2.64% (sample 1) and between +/- 3.44% and +/- 8.60% (sample 2). The method accuracy was evaluated by comparing the results obtained by HPTLC/SIDA-ESI-MS with those from the validated HPTLC/UV method. The results for pharmaceutical and energy drink samples were (ng/band) 99.82 +/- 3.75 and 338.09 +/- 4.87 by HPTLC/SIDA-EST-MS and 104.74 +/- 1.51 and 334.86 +/- 5.63 by HPTLC/UV. According to the F-test (homogeneity of variances) and the t-test (comparison of means) the two methods show no significant difference. The detection and quantification limits were 75 and 250 mu g L(-1) (0.75 and 2.5 ng/band), respectively, which were a factor of 13 lower than those established for HPTLC/UV. The positioning error (RSD +/- 6%) was calculated by comparing HPTLC/SIDA-ESI-MS with HPTLC/ESI-MS. However, using SIDA the positioning error was nullified. HPTLC/SIDA-ESI-MS was demonstrated to be a highly reliable method for the quantification of compounds by planar chromatography coupled online with mass spectrometry. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:1297 / 1303
页数:7
相关论文
共 37 条
[21]   New coupling of planar chromatography with direct analysis in real time mass spectrometry [J].
Morlock, Gertrud ;
Ueda, Yoshihisa .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :243-251
[22]   Determination of isopropylthioxanthone (ITX) in milk, yoghurt and fat by HPTLC-FLD, HPTLC-ESI/MS and HPTLC-DART/MS [J].
Morlock, Gertrud ;
Schwack, Wolfgang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (03) :586-595
[23]   Direct quantitative analysis from thin-layer chromatography plates using matrix-assisted laser desorption/ionization mass spectrometry [J].
Nicola, AJ ;
Gusev, AI ;
Hercules, DM .
APPLIED SPECTROSCOPY, 1996, 50 (12) :1479-1482
[24]  
OKA H, 1993, J FOOD HYG SOC JPN, V34, P517, DOI 10.3358/shokueishi.34.517
[25]   Introduction to time-of-flight secondary ion mass spectrometry application in chromatographic analysis [J].
Orinák, A ;
Arlinghaus, HF ;
Vering, G ;
Orináková, R ;
Hellweg, S .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1084 (1-2) :113-118
[26]   New approaches to coupling TLC with TOF-SIMS [J].
Orinák, A ;
Vering, G ;
Arlinghaus, HF ;
Andersson, JT ;
Halas, L ;
Orinaková, R .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2005, 18 (101) :44-50
[27]   A new interface to couple thin-layer chromatography with laser desorption/atmospheric pressure chemical ionization mass spectrometry for plate scanning [J].
Peng, S ;
Edler, M ;
Ahlmann, N ;
Hoffmann, T ;
Franzke, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (19) :2789-2793
[28]   Thin-layer chromatography combined with diode laser desorption/atmospheric pressure chemical ionization mass spectrometry [J].
Peng, S ;
Ahlmann, N ;
Kunze, K ;
Nigge, W ;
Edler, M ;
Hoffmann, T ;
Franzke, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (16) :1803-1808
[29]   On-line TLC-MS [J].
Prosek, M ;
Milivojevic, L ;
Krizman, M ;
Fir, M .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2004, 17 (06) :420-423
[30]  
SCHOELER KG, 2004, KONSTRUKTION ENTWICK, V5, P40