Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study

被引:13
作者
Bernhardt, TM [1 ]
Rapp-Bernhardt, U [1 ]
Hausmann, T [1 ]
Reichel, G [1 ]
Krause, UW [1 ]
Doehring, W [1 ]
机构
[1] Otto Von Guericke Univ, Univ Hosp, Dept Diagnost Radiol, D-39120 Magdeburg, Germany
关键词
D O I
10.1259/bjr.73.873.11064649
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the diagnostic performance of an additional stationary anti-scatter grid in digital selenium radiography (DSR) compared with images acquired with only an air gap. Chest radiographs were obtained with DSR in 100 patients with and without an anti-scatter grid. Four observers scored 12 anatomical landmarks, catheters and wire cerclages for their visualization in both subsets of images. Statistical analysis was performed using a paired t-test. Anatomical landmarks, catheters and wire cerclages were statistically better visualized in regions of high attenuation when the images were performed with an anti-scatter grid. No statistically significant difference was noted for peripheral regions, nor for sex and weight of the patient between the two modalities. Therefore, an anti-scatter grid is not recommended for chest radiography as it increases the radiation exposure of patients without having a significant impact on visualization for all regions of the chest.
引用
收藏
页码:963 / 968
页数:6
相关论文
共 9 条
[1]   Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography [J].
Bernhardt, TM ;
Otto, D ;
Reichel, G ;
Ludwig, K ;
Seifert, S ;
Kropf, S ;
Rapp-Bernhardt, U .
RADIOLOGY, 1999, 213 (02) :445-454
[2]   STUDIES OF PERFORMANCE OF ANTISCATTER GRIDS IN DIGITAL RADIOGRAPHY - EFFECT ON SIGNAL-TO-NOISE RATIO [J].
CHAN, HP ;
LAM, KL ;
WU, YZ .
MEDICAL PHYSICS, 1990, 17 (04) :655-664
[3]   TECHNICAL EVALUATION OF A DIGITAL CHEST RADIOGRAPHY SYSTEM THAT USES A SELENIUM DETECTOR [J].
CHOTAS, HG ;
FLOYD, CE ;
RAVIN, CE .
RADIOLOGY, 1995, 195 (01) :264-270
[4]   SELENIUM-BASED DIGITAL RADIOGRAPHY OF THE CHEST - RADIOLOGISTS PREFERENCE COMPARED WITH FILM-SCREEN RADIOGRAPHS [J].
FLOYD, CE ;
BAKER, JA ;
CHOTAS, HG ;
DELONG, DM ;
RAVIN, CE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1353-1358
[5]  
Kehler M, 1996, ACTA RADIOL, V37, P332
[6]   GRIDS OR AIR GAPS FOR SCATTER REDUCTION IN DIGITAL RADIOGRAPHY - A MODEL CALCULATION [J].
NEITZEL, U .
MEDICAL PHYSICS, 1992, 19 (02) :475-481
[7]  
OTTO D, 2000, IN PRESS EUR J RADIO
[8]   Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions [J].
SchaeferProkop, CM ;
Prokop, M ;
Schmidt, A ;
Neitzel, U ;
Galanski, M .
RADIOLOGY, 1996, 201 (01) :45-50
[9]   Chest imaging with a selenium detector versus conventional film radiography: A CT-controlled study [J].
vanHeesewijk, HPM ;
vanderGraaf, Y ;
deValois, JC ;
Vos, AJ ;
Feldberg, MAM .
RADIOLOGY, 1996, 200 (03) :687-690