Amperometric phenol biosensor based on sol-gel silicate/Nafion composite film

被引:118
作者
Kim, MA [1 ]
Lee, WY [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
关键词
sol-gel technique; silicate/Nation composite film; tyrosinase; phenolic compounds; amperometric biosensor;
D O I
10.1016/S0003-2670(02)01538-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric biosensor based on tyrosinase immobilized in silicate/Nafion composite film has been developed for the determination of phenolic compounds. The Nafion polymer in the composite was used not only to overcome the brittleness of the pure sol-gel-derived silicate film but also to increase the long-term stability of the biosensor. Tyrosinase was immobilized by a thin film of silicate/Nafion composite on a glassy carbon electrode. Phenolic compounds were determined by the direct reduction of biocatalytically-liberated quinone species at -200 mV versus Ag/AgCl (3 M NaCl). The process parameters for the fabrication of the enzyme electrode and various experimental variables such as pH and operating potential were explored for optimum analytical performance of the enzyme electrode. The biosensor can reach 95% of steady-state current in about 15 s. The sensitivities of the biosensor for catechol and phenol were 200 and 46 mA/M, respectively. A detection limit of 0.35 mM catechol. was obtained with a signal-to-noise ratio of 3. The enzyme electrode retained 74% of its initial activity after 2 weeks of storage in 50 mM phosphate buffer at pH 7. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 45 条
[31]  
OZSOZ M, 1996, ELECTROANAL, V8, P65
[32]   Solid phase microextraction for determining the distribution of chemicals in aqueous matrices [J].
Poerschmann, J ;
Zhang, ZY ;
Kopinke, FD ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :597-600
[33]   Determination of phenolic compounds in water and waste water [J].
Puig, D ;
Barcelo, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (08) :362-375
[34]   Development of tyrosinase based biosensor and its application for monitoring of bioremediation of phenol and phenolic compounds [J].
Svitel, J ;
Miertus, S .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (06) :828-832
[35]  
TILLYER CR, 1991, BIOSENS BIOELECTRON, V6, P560
[36]   Electrochemical applications of silica-based organic-inorganic hybrid materials [J].
Walcarius, A .
CHEMISTRY OF MATERIALS, 2001, 13 (10) :3351-3372
[37]   Silica sol-gel composite film as an encapsulation matrix for the construction of an amperometric tyrosinase-based biosensor [J].
Wang, B ;
Zhang, J ;
Dong, S .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (7-8) :397-402
[38]   Organic-phase enzyme electrode for phenolic determination based on a functionalized sol-gel composite [J].
Wang, BQ ;
Dong, SJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 487 (01) :45-50
[39]   Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material [J].
Wang, BQ ;
Li, B ;
Deng, Q ;
Dong, SJ .
ANALYTICAL CHEMISTRY, 1998, 70 (15) :3170-3174
[40]   Sol-gel materials for electrochemical biosensors [J].
Wang, J .