Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant

被引:33
作者
Afsharpour, Hossein [1 ,2 ,3 ]
Pignol, Jean-Philippe [4 ]
Keller, Brian [4 ]
Carrier, Jean-Francois [5 ]
Reniers, Brigitte [6 ]
Verhaegen, Frank [6 ,7 ]
Beaulieu, Luc [1 ,2 ,3 ]
机构
[1] Univ Laval, CHU Quebec, Dept Radiooncol, Quebec City, PQ G1R 2J6, Canada
[2] Univ Laval, CHU Quebec, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ G1K 7P4, Canada
[4] Univ Toronto, Dept Radiat Oncol, Sunnybrook & Womens Hlth Sci Ctr, Toronto, ON, Canada
[5] CHUM, Hop Notre Dame, Dept Radiol Radiooncol & Med Nucl, Montreal, PQ H2L 4M1, Canada
[6] Univ Hosp Maastricht, GROW, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
[7] McGill Univ, Dept Oncol, Montreal, PQ H3G 1A4, Canada
关键词
I-125 PROSTATE IMPLANTS; MONTE-CARLO; MEDICAL PHYSICS; BRACHYTHERAPY; RADIOTHERAPY; CANCER; MAMMOGRAPHY; THERAPY; TOOLKIT; UPDATE;
D O I
10.1088/0031-9155/55/16/S09
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The impact of tissue heterogeneity and interseed attenuation is studied in post-implant evaluation of five clinical permanent breast Pd-103 seed implants using the Monte Carlo (MC) dose calculation method. Dose metrics for the target (PTV) as well as an organ at risk (skin) are used to visualize the differences between a TG43-like MC method and more accurate MC methods capable of considering the breast tissue heterogeneity as well as the interseed attenuation. PTV dose is reduced when using a breast tissue model instead of water in MC calculations while the dose to the skin is increased. Furthermore, we investigate the effect of varying the glandular/adipose proportion of the breast tissue on dose distributions. The dose to the PTV (skin) decreases (increases) with the increasing adipose proportion inside the breast. In a complete geometry and compared to a TG43-like situation, the average PTV D-90 reduction varies from 3.9% in a glandular breast to 35.5% when the breast consists entirely of adipose. The skin D-10 increases by 28.2% in an entirely adipose breast. The results of this work show the importance of an accurate and patient-dependent breast tissue model to be used in the dosimetry for this kind of low energy implant.
引用
收藏
页码:4547 / 4561
页数:15
相关论文
共 37 条
[1]
A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants [J].
Afsharpour, Hossein ;
D'Amours, Michel ;
Cote, Benoit ;
Carrier, Jean-Francois ;
Verhaegen, Frank ;
Beaulieu, Luc .
MEDICAL PHYSICS, 2008, 35 (08) :3671-3681
[2]
GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[3]
ATTIX FH, 2004, INTRO RADIOLOGICAL P, P307
[4]
Comparison of x-ray cross sections for diagnostic and therapeutic medical physics [J].
Boone, JM ;
Chavez, AE .
MEDICAL PHYSICS, 1996, 23 (12) :1997-2005
[5]
Postimplant dosimetry using a Monte Carlo dose calculation engine:: A new clinical standard [J].
Carrier, Jean-Francois ;
D'Amours, Michel ;
Verhaegen, Frank ;
Reniers, Brigitte ;
Martin, Andre-Guy ;
Vigneault, Eric ;
Beaulieu, Luc .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04) :1190-1198
[6]
Impact of interseed attenuation and tissue composition for permanent prostate implants [J].
Carrier, JF ;
Beaulieu, L ;
Therriault-Proulx, F ;
Roy, R .
MEDICAL PHYSICS, 2006, 33 (03) :595-604
[7]
Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics [J].
Carrier, JF ;
Archambault, L ;
Beaulieu, L ;
Roy, R .
MEDICAL PHYSICS, 2004, 31 (03) :484-492
[8]
Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants [J].
Chibani, O ;
Williamson, JF ;
Todor, D .
MEDICAL PHYSICS, 2005, 32 (08) :2557-2566
[9]
Dose-volume conundrum for response of prostate cancer to brachytherapy: Summary dosimetric measures and their relationship to tumor control probability [J].
D'Souza, WD ;
Thames, HD ;
Kuban, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (05) :1540-1548
[10]
CERR: A computational environment for radiotherapy research [J].
Deasy, JO ;
Blanco, AI ;
Clark, VH .
MEDICAL PHYSICS, 2003, 30 (05) :979-985