The volume effect of detectors in the dosimetry of small fields used in IMRT

被引:235
作者
Laub, WU [1 ]
Wong, T
机构
[1] Univ Tubingen, Dept Med Phys, D-72074 Tubingen, Germany
[2] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI USA
关键词
IMRT; quality assurance; small field dosimetry; volume effect;
D O I
10.1118/1.1544678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study we investigate the effect of detector size in the dosimetry of small fields and steep dose gradients with a particular emphasis on IMRT measurements. Comparisons of calculated and measured cross-profiles and absolute dose values of IMRT treatment plans are presented. As a consequence of the finite size of the detector that was used for the commissioning of the IMRT tool, local discrepancies of more than 10% are found between calculated cross-profiles of intensity modulated beams and intensity modulated profiles measured with film. Absolute dose measurements of intensity modulated fields with a 0.6 cm(3) Farmer chamber show significant differences of more than 6% between calculated and measured dose values at the isocenter of an IMRT treatment plan. Differences of not more than 2% are found in the same experiment for dose values measured with a 0.015 cm(3) pinpoint ion chamber. A method to correct for the spatial response of finite-sized detectors and to obtain the "real" penumbra width of cross-profiles from measurements is introduced. Output factor measurements are performed with different detectors and are presented as a function of detector size for a 1 x 1 cm(2) field. Because of its high spatial resolution and water equivalence, a diamond detector is found to be suitable as an alternative to other detectors used for small field dosimetry as there are photographic and photochromic film, TLDs, or water-equivalent scintillation detectors. 2003 American Association of Physicists in Medicine.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 12 条
[1]   Rapid radiographic film calibration for IMRT verification using automated MLC fields [J].
Childress, NL ;
Dong, L ;
Rosen, II .
MEDICAL PHYSICS, 2002, 29 (10) :2384-2390
[2]   Dosimetry of therapeutic photon beams using an extended dose range film [J].
Esthappan, J ;
Mutic, S ;
Harms, WB ;
Dempsey, JF ;
Low, DA .
MEDICAL PHYSICS, 2002, 29 (10) :2438-2445
[3]   Experimental determination of the convolution kernel for the study of the spatial response of a detector [J].
Garcia-Vicente, F ;
Delgado, JM ;
Peraza, C .
MEDICAL PHYSICS, 1998, 25 (02) :202-207
[4]   Investigation of photon beam output factors for conformal radiation therapy -: Monte Carlo simulations and measurements [J].
Haryanto, F ;
Fippel, M ;
Laub, W ;
Dohm, O ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (11) :N133-N143
[5]   DOSE-RATE DEPENDENCE OF A PTW DIAMOND DETECTOR IN THE DOSIMETRY OF A 6 MV PHOTON-BEAM [J].
HOBAN, PW ;
HEYDARIAN, M ;
BECKHAM, WA ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08) :1219-1229
[6]  
Huang C., 2000, International Journal of Radiation Oncology Biology Physics, V48, P175, DOI 10.1016/S0360-3016(00)80144-3
[7]   Energy and dose rate dependence of a diamond detector in the dosimetry of 4-25 MV photon beams [J].
Laub, WU ;
Kaulich, TW ;
Nusslin, F .
MEDICAL PHYSICS, 1997, 24 (04) :535-536
[8]   The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy [J].
Martens, C ;
De Wagter, C ;
De Neve, W .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :2519-2530
[9]   DOSIMETRY OF 6-MV X-RAY-BEAM PENUMBRA [J].
METCALFE, P ;
KRON, T ;
ELLIOTT, A ;
WONG, T ;
HOBAN, P .
MEDICAL PHYSICS, 1993, 20 (05) :1439-1445
[10]   Intensity-modulated radiation therapy (IMRT) reduces small bowel, rectum, and bladder doses in patients with cervical cancer receiving pelvic and para-aortic irradiation [J].
Portelance, L ;
Chao, KSC ;
Grigsby, PW ;
Bennet, H ;
Low, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01) :261-266