PEROXIDASE-MODIFIED CARBON-FIBER MICROELECTRODES IN FLOW-THROUGH DETECTION OF HYDROGEN-PEROXIDE AND ORGANIC PEROXIDES

被引:59
作者
CSOREGI, E [1 ]
GORTON, L [1 ]
MARKOVARGA, G [1 ]
TUDOS, AJ [1 ]
KOK, WT [1 ]
机构
[1] UNIV AMSTERDAM, DEPT ANALYT CHEM, 1018 WV AMSTERDAM, NETHERLANDS
关键词
D O I
10.1021/ac00093a012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mediatorless amperometric microbiosensors, prepared by immobilizing two different peroxidases [horseradish peroxidase (HRP) or peroxidase from Arthromyces ramosus (ARP)] on high-modulus-type carbon fibers, were applied for detection in flowing solution. The preparation and performance of the enzyme-modified carbon fibers were studied. An electrochemical flow-through cell containing the fiber electrode was evaluated and optimized. The influence of the electrode dimensions and the flow rate on the sensitivity and the sample dispersion in the cell was studied by use of bare and enzyme-modified electrodes. The peak broadening was found to be determined by the geometry of the now cell. The response time of the enzyme-modified electrode was short (<4 s) and did not contribute significantly to the peak broadening. When operated in a flow injection (FI) system, hydrogen peroxide and organic peroxides could be detected with the enzyme-modified electrodes at an applied potential of -0.05 V vs Ag/AgCl. With the optimized cell low noise levels were obtained (<5 pA), allowing detection limits of 0.3, 6.0, and 20.0 mu M for hydrogen peroxide, cumol hydroperoxide, and 2-butanone peroxide, respectively.
引用
收藏
页码:3604 / 3610
页数:7
相关论文
共 50 条
  • [41] AMPEROMETRIC DETECTION OF CATECHOLS IN CAPILLARY ZONE ELECTROPHORESIS WITH NORMAL AND MICELLAR SOLUTIONS
    WALLINGFORD, RA
    EWING, AG
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (03) : 258 - 263
  • [42] MINIATURIZED FLEXIBLE AMPEROMETRIC LACTATE PROBE
    WANG, DL
    HELLER, A
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (08) : 1069 - 1073
  • [43] AMPEROMETRIC BIOSENSING OF ORGANIC PEROXIDES WITH PEROXIDASE-MODIFIED ELECTRODES
    WANG, J
    FREIHA, B
    NASER, N
    ROMERO, EG
    WOLLENBERGER, U
    OZSOZ, M
    EVANS, O
    [J]. ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) : 81 - 88
  • [44] MINIATURIZED GLUCOSE SENSORS BASED ON ELECTROCHEMICAL CODEPOSITION OF RHODIUM AND GLUCOSE-OXIDASE ONTO CARBON-FIBER ELECTRODES
    WANG, J
    ANGNES, L
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (04) : 456 - 459
  • [45] FLOW CELL BASED ON GLUCOSE OXIDASE-MODIFIED CARBON-FIBER ULTRAMICROELECTRODE
    WANG, J
    LI, RL
    LIN, MS
    [J]. ELECTROANALYSIS, 1989, 1 (02) : 151 - 154
  • [46] ONLINE ORGANIC-PHASE ENZYME DETECTOR
    WANG, J
    LIN, YH
    [J]. ANALYTICA CHIMICA ACTA, 1993, 271 (01) : 53 - 58
  • [47] SCANNING ON-COLUMN VOLTAMMETRIC DETECTOR FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY
    WHITE, JG
    STCLAIRE, RL
    JORGENSON, JW
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (02) : 293 - 298
  • [48] BULK MODIFIED ENZYME ELECTRODES FOR REAGENTLESS DETECTION OF PEROXIDES
    WOLLENBERGER, U
    WANG, J
    OZSOZ, M
    GONZALEZROMERO, E
    SCHELLER, F
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1991, 26 (02): : 287 - 296
  • [49] MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY OF VITAMIN B-6 WITH ELECTROCHEMICAL DETECTION
    YIK, YF
    LEE, HK
    LI, SFY
    KHOO, SB
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 585 (01): : 139 - 144
  • [50] MEDIATED GLUCOSE SENSOR USING A CYLINDRICAL MICROELECTRODE
    YOKOYAMA, K
    LEE, SM
    TAMIYA, E
    KARUBE, I
    NAKAJIMA, K
    UCHIYAMA, S
    SUZUKI, S
    AKIYAMA, M
    MASUDA, Y
    [J]. ANALYTICA CHIMICA ACTA, 1992, 263 (1-2) : 101 - 110