CHOLESTEROL BIOSENSORS PREPARED BY ELECTROPOLYMERIZATION OF PYRROLE

被引:44
作者
TRETTNAK, W [1 ]
LIONTI, I [1 ]
MASCINI, M [1 ]
机构
[1] UNIV FLORENCE,DIPARTIMENTO SANITA PUBBL EPIDEMIOL & CHIM ANALIZ AMBIENTALE,I-50121 FLORENCE,ITALY
关键词
CHOLESTEROL; POLYPYRROLE; CHOLESTEROL OXIDASE; FLOW INJECTION ANALYSIS;
D O I
10.1002/elan.1140050908
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors for cholesterol were prepared by electropolymerization of pyrrole in solutions of 0.1 M phosphate buffer containing 10 mm NaClO4 and 15 to 55 IU/mL of cholesterol oxidase at a potential of 800 mV versus a calomel reference electrode (3 M KCl). The sensors were tested for their response toward cholesterol in batch, flow-through, and flow-injection systems by detection of the hydrogen peroxide formed in the enzymatic reaction. Flow-injection analysis (FIA) measurements with an injection loop of 50 muL were performed with a high reproducibility in the range of 0 to 250 muM cholesterol with solutions of constant detergent concentration (1% Triton X-100 in 0.1 M phosphate buffer of pH 7.0) and at a flow rate of 0.2 mL/min. At this flow rate, the detection limit was approximately 5 muM cholesterol and the sample throughput was 25 injections per hour. The response of the sensors toward ascorbic and uric acid was investigated.
引用
收藏
页码:753 / 763
页数:11
相关论文
共 36 条
  • [1] ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS
    BARTLETT, PN
    TEBBUTT, P
    TYRRELL, CH
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (02) : 138 - 142
  • [2] ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE
    BARTLETT, PN
    WHITAKER, RG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2): : 37 - 48
  • [3] BESOZZI M, 1989, ESPRESSIONE RISULTAT, P67
  • [4] ASSESSMENT OF METHODOLOGIES FOR COLORIMETRIC CHOLESTEROL ASSAY OF MEATS
    BOHAC, CE
    RHEE, KS
    CROSS, HR
    ONO, K
    [J]. JOURNAL OF FOOD SCIENCE, 1988, 53 (06) : 1642 - &
  • [5] BROWN SS, 1980, CHEM DIAGNOSIS DISEA, P1147
  • [6] THE DETERMINATION OF TOTAL SERUM-CHOLESTEROL BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    CARPENTER, A
    PURDY, WC
    [J]. ANALYTICAL LETTERS, 1990, 23 (03) : 425 - 435
  • [7] INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM
    CENTONZE, D
    GUERRIERI, A
    MALITESTA, C
    PALMISANO, F
    ZAMBONIN, PG
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09): : 729 - 733
  • [8] CENTONZE D, 1992, ANN CHIM-ROME, V82, P219
  • [9] CHEILLAN F, 1991, ANN CHIM-ROME, V81, P673
  • [10] ELECTROCHEMICAL RESPONSE OF AN ENZYME-LOADED POLYANILINE FILM
    COOPER, JC
    HALL, EAH
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (07) : 473 - 485