RAPID FLUORESCENCE FLOW-INJECTION IMMUNOASSAY USING A NOVEL PERFUSION CHROMATOGRAPHIC MATERIAL

被引:28
作者
PALMER, DA [1 ]
EVANS, M [1 ]
MILLER, JN [1 ]
FRENCH, MT [1 ]
机构
[1] WELLCOME FDN LTD,DEPT BIOANAL & DRUG METAB,BECKENHAM BR3 3BS,KENT,ENGLAND
关键词
PERFUSION CHROMATOGRAPHIC MATRIX; FLOW INJECTION; FLUORESCENCE IMMUNOASSAY; PROTEIN A; TESTOSTERONE;
D O I
10.1039/an9941900943
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid fluorescence how injection immunoassay has been developed for a model analyte (testosterone) using a novel perfusion chromatographic matrix (POROS) coated with protein A. The fluorophore used was Texas Red. The perfusion matrix contains two classes of pores, which radically enhances mass transport and provides a very high capacity unaffected by how rate. For each assay the antibody-protein A reaction takes place at nearly neutral pH, and the complexes are eluted at acidic pH. Both preincubation and on-line assay formats were investigated. The total time for the pre-incubation and on-line assays was less than 4 and 6 min, respectively. Serum testosterone was determined by this method and good relative standard deviations and recoveries were achieved. The use of an avidin-biotin system in the preparation of the testosterone-Texas Red conjugate is also described.
引用
收藏
页码:943 / 947
页数:5
相关论文
共 12 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]  
DEALWIS WU, 1985, ANAL CHEM, V57, P2754
[3]   AN ONLINE IMMUNOASSAY METHOD FOR THEOPHYLLINE USING A PROTEIN-A IMMUNOREACTOR [J].
FERNANDEZHERNANDO, P ;
MILLER, JN .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (10-12) :1121-1123
[4]   DUAL-COLUMN IMMUNOASSAYS USING PROTEIN-G AFFINITY-CHROMATOGRAPHY [J].
JANIS, LJ ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1901-1906
[5]  
LEE IH, 1988, MIKROCHIM ACTA, P207
[6]   LIPOSOME FLOW-INJECTION IMMUNOASSAY - IMPLICATIONS FOR SENSITIVITY, DYNAMIC-RANGE, AND ANTIBODY REGENERATION [J].
LOCASCIOBROWN, L ;
PLANT, AL ;
HORVATH, V ;
DURST, RA .
ANALYTICAL CHEMISTRY, 1990, 62 (23) :2587-2593
[7]   FLOW-INJECTION IMMUNOASSAY USING A PROTEIN-A IMMUNOREACTOR [J].
MILLER, JN ;
PALMER, DA ;
FRENCH, MT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (10-12) :1115-1120
[8]  
PAL SB, 1987, ENZYME LABELLED IMMU, P91
[9]   FLOW-INJECTION ELECTROCHEMICAL ENZYME-IMMUNOASSAY FOR THEOPHYLLINE USING A PROTEIN-A IMMUNOREACTOR AND P-AMINOPHENYL PHOSPHATE-P-AMINOPHENOL AS THE DETECTION SYSTEM [J].
PALMER, DA ;
EDMONDS, TE ;
SEARE, NJ .
ANALYST, 1992, 117 (11) :1679-1682
[10]   PERFUSION CHROMATOGRAPHY [J].
REGNIER, FE .
NATURE, 1991, 350 (6319) :634-635