INTERLABORATORY DETERMINATION OF OXYGEN IN SILICON FOR CERTIFIED REFERENCE MATERIALS

被引:12
作者
MURRAY, R
GRAFF, K
PAJOT, B
STRIJCKMANS, K
VANDENDRIESSCHE, S
GRIEPINK, B
MARCHANDISE, H
机构
[1] TELEFUNKEN ELECTR GMBH,W-7100 HEILBRONN,GERMANY
[2] UNIV PARIS 07,PHYS SOLIDES GRP,F-75251 PARIS 05,FRANCE
[3] STATE UNIV GHENT,INST NUCL SCI,ANALYT CHEM LAB,B-9000 GENT,BELGIUM
[4] COMMISS EUROPEAN COMMUNITIES,COMMUNITY BUR REF,B-1049 BRUSSELS,BELGIUM
关键词
D O I
10.1149/1.2069126
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The oxygen content and relative transmission of Czochralski silicon containing interstitial oxygen in three different concentrations has been determined in a multilaboratory exercise to produce sets of certified reference materials (CRMs). A calibration factor of (3.02 +/- 0.19) x 10(17) cm-2 linking the oxygen concentration to the peak absorption of the interstitial oxygen band can be derived in good agreement with the International Oxygen Coefficient 1988 (IOC-88) study. This calibration factor corresponds to a measurement temperature of 310 K. However, the present work has identified differences in the infrared data of the order of 5 % between measurements made with dispersive and Fourier transform spectrometers (FTS). These differences arise from the emissivity of the samples which is detected in many FTS as a spurious contribution to the oxygen absorption. It follows that the FTS data have to be corrected generally so that they agree with the results obtained with dispersive spectrometers (DS). Consequently, the calibration factor was deduced from DS results only. It is proposed that the aptitude of different infrared (IR) instruments to measure accurately the oxygen absorption coefficient can be tested with the aid of the CRM sets with certified oxygen concentrations and relative transmissions.
引用
收藏
页码:3582 / 3587
页数:6
相关论文
共 18 条
[1]   INTERLABORATORY DETERMINATION OF THE CALIBRATION FACTOR FOR THE MEASUREMENT OF THE INTERSTITIAL OXYGEN-CONTENT OF SILICON BY INFRARED-ABSORPTION [J].
BAGHDADI, A ;
BULLIS, WM ;
CROARKIN, MC ;
LI, YZ ;
SCACE, RI ;
SERIES, RW ;
STALLHOFER, P ;
WATANABE, M .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (07) :2015-2024
[2]   THE REMOVAL OF DETECTOR PORT RADIATION EFFECTS IN POWER TRANSMISSION OR REFLECTION FOURIER-TRANSFORM SPECTROSCOPY [J].
BIRCH, JR ;
NICOL, EA .
INFRARED PHYSICS, 1987, 27 (03) :159-165
[3]  
HE H, 1983, TALANTA, V30, P761
[4]   DETERMINATION OF CONVERSION FACTOR FOR INFRARED MEASUREMENT OF OXYGEN IN SILICON [J].
IIZUKA, T ;
TAKASU, S ;
TAJIMA, M ;
ARAI, T ;
NOZAKI, T ;
INOUE, N ;
WATANABE, M .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1985, 132 (07) :1707-1713
[5]  
MEIERAN ES, 1980, NATO ADV STUDY SERIE
[6]  
OSHAWA A, 1981, APPL PHYS LETT, V38, P787
[7]  
PAJOT B, 1977, ANALUSIS, V5, P293
[8]   QUANTITATIVE SPECTROSCOPY OF INTERSTITIAL OXYGEN IN SILICON [J].
PAJOT, B ;
STEIN, HJ ;
CALES, B ;
NAUD, C .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1985, 132 (12) :3034-3037
[9]   DETERMINATION OF OXYGEN IN SILICON BY PHOTON-ACTIVATION ANALYSIS FOR CALIBRATION OF THE INFRARED-ABSORPTION [J].
RATH, HJ ;
STALLHOFER, P ;
HUBER, D ;
SCHMITT, BF .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1984, 131 (08) :1920-1922
[10]   CORRECTION FACTORS FOR THE DETERMINATION OF OXYGEN IN SILICON BY IR SPECTROMETRY [J].
SCHOMANN, F ;
GRAFF, K .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (07) :2025-2031