腰椎棘突间内固定器生物力学测试方法的研究进展

被引:3
作者
宋超
刘祖德
机构
[1] 上海交通大学医学院附属仁济医院骨科
关键词
D O I
暂无
中图分类号
R687.3 [骨骼手术];
学科分类号
100220 [骨科学];
摘要
<正>随着材料学和生物力学发展,传统的脊柱内固定方法不断改进,新型内固定器械不断涌现。而新的内固定器械在临床应用前应该在实验室进行生物力学综合评价,从而选出最合适的内固定器。因此,对脊柱内固定器械的生物力学研究已成为目前脊柱外科生物力学研究的重要课题。随着非融合技术成为国内外脊柱外科界的研究热点,
引用
收藏
页码:870 / 873
页数:4
相关论文
共 10 条
[1]
Biomechanics of a Novel Minimally Invasive Lumbar Interspinous Spacer: Effects on Kinematics; Facet Loads; and Foramen Height.[J].Bruno C.R. Lazaro;Leonardo B.C. Brasiliense;Anna G.U. Sawa;Phillip M. Reyes;Nicholas Theodore;Volker K.H. Sonntag;Neil R. Crawford.Neurosurgery.2010, 3 Op
[2]
The effect of dynamic, semi-rigid implants on the range of motion of lumbar motion segments after decompression [J].
Schulte, Tobias L. ;
Hurschler, Christof ;
Haversath, Marcel ;
Liljenqvist, Ulf ;
Bullmann, Viola ;
Filler, Timm J. ;
Osada, Nani ;
Fallenberg, Eva-Maria ;
Hackenberg, Lars .
EUROPEAN SPINE JOURNAL, 2008, 17 (08) :1057-1065
[3]
Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure [J].
Wilke, Hans-Joachim ;
Drumm, J. ;
Haeussler, K. ;
Mack, C. ;
Steudel, W. -I. ;
Kettler, A. .
EUROPEAN SPINE JOURNAL, 2008, 17 (08) :1049-1056
[4]
New interspinous implant evaluation using an in vitro biomechanical study combined with a finite-element analysis [J].
Lafage, Virginie ;
Gangnet, Nicolas ;
Senegas, Jacques ;
Lavaste, Francois ;
Skalli, Wafa .
SPINE, 2007, 32 (16) :1706-1713
[5]
Influence of X stop on neural foramina and spinal canal area in spinal stenosis [J].
Siddiqui, Manal ;
Karadimas, Efthimios ;
Nicol, Malcolm ;
Smith, Francis W. ;
Wardlaw, Douglas .
SPINE, 2006, 31 (25) :2958-2962
[6]
The effect of an interspinous process implant on facet loading during extension [J].
Wiseman, CM ;
Lindsey, DP ;
Fredrick, AD ;
Yerby, SA .
SPINE, 2005, 30 (08) :903-907
[7]
The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine [J].
Lindsey, DP ;
Swanson, KE ;
Fuchs, P ;
Hsu, KY ;
Zucherman, JF ;
Yerby, SA .
SPINE, 2003, 28 (19) :2192-2197
[8]
The effects of an interspinous implant on intervertebral disc pressures [J].
Swanson, KE ;
Lindsey, DP ;
Hsu, KY ;
Zucherman, JF ;
Yerby, SA .
SPINE, 2003, 28 (01) :26-32
[9]
Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants [J].
Wilke H.-J. ;
Wenger K. ;
Claes L. .
European Spine Journal, 1998, 7 (2) :148-154
[10]
Biomechanical analysis of multilevel fixation methods in the lumbar spine [J].
Glazer, PA ;
Colliou, O ;
Klisch, SM ;
Bradford, DS ;
Bueff, HU ;
Lotz, JC .
SPINE, 1997, 22 (02) :171-182