Diode/magnetic tunnel junction cell for fully scalable matrix-based biochip

被引:17
作者
Cardoso, F. A.
Ferreira, H. A.
Conde, J. P.
Chu, V.
Freitas, P. P.
Vidal, D.
Germano, J.
Sousa, L.
Piedade, M. S.
Costa, B. A.
Lemos, J. M.
机构
[1] INESC Microsyst & Nanotechnol, P-1000029 Lisbon, Portugal
[2] Univ Tecn Lisboa, Inst Super Tecn, P-1000029 Lisbon, Portugal
[3] INESC Invest & Desenvolvimento, P-1000029 Lisbon, Portugal
关键词
D O I
10.1063/1.2165148
中图分类号
O59 [应用物理学];
学科分类号
摘要
Magnetoresistive biochips have been recently introduced for the detection of biomolecular recognition. In this work, the detection site incorporates a thin-film diode in series with a magnetic tunnel junction (MTJ), leading to a matrix-based biochip that can be easily scaled up to screen large numbers of different target analytes. The fabricated 16x16 cell matrix integrates hydrogenated amorphous silicon (a-Si:H) diodes with aluminum oxide barrier MTJ. Each detection site also includes a U-shaped current line for magnetically assisted target concentration at probe sites. The biochip is being integrated in a portable, credit card size electronics control platform. Detection of 250 nm diameter magnetic nanoparticles by one of the matrix cells is demonstrated. (C) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 10 条
[1]   Planar Hall effect sensor for magnetic micro- and nanobead detection [J].
Ejsing, L ;
Hansen, MF ;
Menon, AK ;
Ferreira, HA ;
Graham, DL ;
Freitas, PP .
APPLIED PHYSICS LETTERS, 2004, 84 (23) :4729-4731
[2]   Rapid DNA hybridization based on ac field focusing of magnetically labeled target DNA [J].
Ferreira, HA ;
Feliciano, N ;
Graham, DL ;
Clarke, LA ;
Amaral, MD ;
Freitas, PP .
APPLIED PHYSICS LETTERS, 2005, 87 (01)
[3]   Detection of cystic fibrosis related DNA targets using AC field focusing of magnetic labels and spin-valve sensors [J].
Ferreira, HA ;
Graham, DL ;
Feliciano, N ;
Clarke, LA ;
Amaral, MD ;
Freitas, PP .
IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) :4140-4142
[4]  
Freitas P.P., 2004, Magneto Electronics
[5]   Magnetoresistive-based biosensors and biochips [J].
Graham, DL ;
Ferreira, HA ;
Freitas, PP .
TRENDS IN BIOTECHNOLOGY, 2004, 22 (09) :455-462
[6]   Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors [J].
Rife, JC ;
Miller, MM ;
Sheehan, PE ;
Tamanaha, CR ;
Tondra, M ;
Whitman, LJ .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 107 (03) :209-218
[7]   Comparison of a prototype magnetoresistive biosensor to standard fluorescent DNA detection [J].
Schotter, J ;
Kamp, PB ;
Becker, A ;
Pühler, A ;
Reiss, G ;
Brückl, H .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1149-1156
[8]   In situ detection of single micron-sized magnetic beads using magnetic tunnel junction sensors [J].
Shen, WF ;
Liu, XY ;
Mazumdar, D ;
Xiao, G .
APPLIED PHYSICS LETTERS, 2005, 86 (25) :1-3
[9]   Vertical integration of a spin dependent tunnel junction with an amorphous Si diode for MRAM application [J].
Sousa, RC ;
Freitas, PP ;
Chu, V ;
Conde, JP .
IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (05) :2832-2834
[10]   High-current-density thin-film silicon diodes grown at low temperature [J].
Wang, Q ;
Ward, S ;
Duda, A ;
Hu, J ;
Stradins, P ;
Crandall, RS ;
Branz, HM ;
Perlov, C ;
Jackson, W ;
Mei, P ;
Taussig, C .
APPLIED PHYSICS LETTERS, 2004, 85 (11) :2122-2124