A label-free electrochemical impedance immunosensor based on AuNPs/PAMAM-MWCNT-Chi nanocomposite modified glassy carbon electrode for detection of Salmonella typhimurium in milk

被引:136
作者
Dong, Jing [1 ]
Zhao, Han [2 ]
Xu, Minrong [1 ]
Ma, Qiang [1 ]
Ai, Shiyun [1 ]
机构
[1] Shandong Agr Univ, Coll Chem & Mat Sci, Tai An 271018, Shandong, Peoples R China
[2] Weifang Entry Exit Inspect & Quarantine Bur Peopl, Weifang 261041, Shangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical impedance immunosensor; Poly(amidoamine); Multiwalled carbon nanotubes; Gold nanoparticles; Salmonella typhimurium; ESCHERICHIA-COLI O157-H7; METAL NANOPARTICLES; RAPID DETECTION; NANOTUBES; IMMOBILIZATION; DENDRIMERS;
D O I
10.1016/j.foodchem.2013.04.098
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A sensitive and stable label-free electrochemical impedance immunosensor for the detection of Salmonella typhimurium was developed by immobilising anti-Salmonella antibodies onto the gold nanoparticles and poly(amidoamine)-multiwalled carbon nanotubes-chitosan nanocomposite film modified glassy carbon electrode (AuNPs/PAMAM-MWCNT-Chi/GCE). Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to verify the stepwise assembly of the immunosensor. Co-addition of MWCNT, PAMAM and AuNPs greatly enhanced the sensitivity of the immunosensor. The immobilisation of antibodies and the binding of Salmonella cells to the modified electrode increased the electrontransfer resistance (R), which was directly measured with EIS using [Fe(CN)(6)](3-14)- as a redox probe. A linear relationship of Re, and Salmonella concentration was obtained in the Salmonella concentration range of 1.0 x 10(3) to 1.0 x 10(7) CFU mL(-1) with a detection limit of 5.0 x 10(2) CFU mL(-1). Additionally, the proposed method was successfully applied to determine S. typhimurium content in milk samples with satisfactory results. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1980 / 1986
页数:7
相关论文
共 31 条
[11]   The detection of Salmonella serovars from animal feed and raw chicken using a combined immunomagnetic separation and ELISA method [J].
Mansfield, LP ;
Forsythe, SJ .
FOOD MICROBIOLOGY, 2001, 18 (04) :361-366
[12]   Carbon nanotubes in analytical sciences [J].
Merkoçi, A .
MICROCHIMICA ACTA, 2006, 152 (3-4) :157-174
[13]   New materials for electrochemical sensing V:: Nanoparticles for DNA labeling [J].
Merkoçi, A ;
Aldavert, M ;
Marín, S ;
Alegret, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) :341-349
[14]   A methodology for rapid detection of Salmonella typhimurium using label-free electrochemical impedance spectroscopy [J].
Nandakumar, Vivek ;
La Belle, Jeffrey T. ;
Reed, Justin ;
Shah, Miti ;
Cochran, Douglas ;
Joshi, Lokesh ;
Alford, T. L. .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :1039-1042
[15]   CHARACTERIZATION OF STARBURST DENDRIMERS BY ELECTRON-PARAMAGNETIC-RESONANCE .2. POSITIVELY CHARGED NITROXIDE RADICALS OF VARIABLE CHAIN-LENGTH USED AS SPIN PROBES [J].
OTTAVIANI, MF ;
COSSU, E ;
TURRO, NJ ;
TOMALIA, DA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (15) :4387-4398
[16]   An electrochemical immunosensor based on antibody-nanowire conjugates [J].
Pampalakis, Georgios ;
Kelley, Shana O. .
ANALYST, 2009, 134 (03) :447-449
[17]   Dendritic polymer macromolecular carriers for drug delivery [J].
Patri, AK ;
Majoros, IJ ;
Baker, JR .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2002, 6 (04) :466-471
[18]   Substrate-enhanced electroless deposition of metal nanoparticles on carbon nanotubes [J].
Qu, LT ;
Dai, LM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (31) :10806-10807
[19]   Electrodeposition of noble metal nanoparticles on carbon nanotubes [J].
Quinn, BM ;
Dekker, C ;
Lemay, SG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (17) :6146-6147
[20]   Immunobiosensor chips for detection of Escherichia coli O157:H7 using electrochemical impedance spectroscopy [J].
Ruan, CM ;
Yang, LJ ;
Li, YB .
ANALYTICAL CHEMISTRY, 2002, 74 (18) :4814-4820