Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT

被引:62
作者
Ay, MR [1 ]
Zaidi, H [1 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva, Switzerland
关键词
D O I
10.1088/0031-9155/50/20/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An x-ray computed tomography (CT) simulator based on the Monte Carlo N-particle radiation transport computer code (MCNP4C) was developed for simulation of both fan- and cone-beam CT scanners. A user-friendly interface running under Matlab 6.5.1 creates the scanner geometry at different views as MCNP4C's input file. The full simulation of x-ray tube, phantom and detectors with single-slice, multi-slice and flat detector configurations was considered. The simulator was validated through comparison with experimental measurements of different nonuniform phantoms with varying sizes on both a clinical and a small-animal CT scanner. There is good agreement between the simulated and measured projections and reconstructed images. Thereafter, the effects of bow-tie filter, phantom size and septa length on scatter distribution in fan-beam CT were studied in detail. The relative difference between detected total, primary and scatter photons for septa length varying between 0 and 95 mm is 11.2%, 1.9% and 84.1%, respectively, whereas the scatter-to-primary ratio decreases by 83.8%. The developed simulator is a powerful tool for evaluating the effect of physical, geometrical and other design parameters on scanner performance and image quality in addition to offering a versatile tool for investigating potential artefacts and correction schemes when using CT-based attenuation correction on dual-modality PET/CT units.
引用
收藏
页码:4863 / 4885
页数:23
相关论文
共 39 条
[11]   Experimental validation of a rapid Monte Carlo based micro-CT simulator [J].
Colijn, AP ;
Zbijewski, W ;
Sasov, A ;
Beekman, FJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (18) :4321-4333
[12]   Accelerated simulation of cone beam X-ray scatter projections [J].
Colijn, AP ;
Beekman, FJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :584-590
[13]  
CRISTY M, 1987, ORNLTM8381VU7
[14]   Multi-slice spiral CT simulator for dynamic cardio-pulmonary studies. [J].
De Francesco, S ;
da Silva, AMF .
MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 :305-316
[15]  
DEMAN B, 2001, THESIS LEUVEN U BELG
[16]   A LABORATORY CT SCANNER FOR DYNAMIC IMAGING [J].
DRANGOVA, M ;
FENSTER, A .
MEDICAL PHYSICS, 1994, 21 (06) :731-740
[17]   Effect of scattered radiation on image noise in cone beam CT [J].
Endo, M ;
Tsunoo, T ;
Nakamori, N ;
Yoshida, K .
MEDICAL PHYSICS, 2001, 28 (04) :469-474
[18]   COMPTON SCATTER EFFECTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH .
MEDICAL PHYSICS, 1982, 9 (06) :860-867
[19]  
Hasegawa BH, 2006, QUANTITATIVE ANALYSIS IN NUCLEAR MEDICINE IMAGING, P35, DOI 10.1007/0-387-25444-7_2
[20]   Analytical models for multi-slice helical CT performance parameters [J].
Hsieh, J .
MEDICAL PHYSICS, 2003, 30 (02) :169-178