Physiological noise reduction for arterial spin labeling functional MRI

被引:87
作者
Restom, Khaled
Behzadi, Yashar
Liu, Thomas T.
机构
[1] Univ Calif San Diego, Ctr Funct MRI, Ctr Funct Magnet Resonance Imaging, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Ctr Funct MRI, Dept Radiol, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Bioengn, La Jolla, CA USA
关键词
D O I
10.1016/j.neuroimage.2006.01.026
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Three methods for the reduction of physiological noise in arterial spin labeling (ASL) functional magnetic resonance imaging (fMRI) are presented and compared. The methods are based upon a general linear model of the ASL measurement process and on a previously described retrospective image-based method (RETROICOR) for physiological noise reduction in blood oxygenation level dependent fMRI. In the first method the contribution of physiological noise to the interleaved control and tag images that comprise the ASL time series are assumed to be equal, while in the second method this assumption is not made. For the third method, it is assumed that physiological noise primarily impacts the perfusion time series obtained from the filtered subtraction of the control and tag images. The methods were evaluated using studies of functional activity in the visual cortex and the hippocampal region. The first and second methods significantly improved statistical performance in both brain regions, whereas the third method did not provide a significant gain. The second method provided significantly better performance than the first method in the hippocampal region, whereas the differences between methods were less pronounced in visual cortex. The improved performance of the second method in the hippocampal region appears to reflect the relatively greater effect of cardiac fluctuations in this brain region. The proposed methods should be particularly useful for ASL studies of cognitive processes where the intrinsic signal to noise ratio is typically lower than for studies of primary sensory regions. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1104 / 1115
页数:12
相关论文
共 39 条
[11]  
HERNANDEZGARCIA L, 2005, P ISMRM 13 SCI M MIA, P1579
[12]   RETROSPECTIVE ESTIMATION AND CORRECTION OF PHYSIOLOGICAL FLUCTUATION IN FUNCTIONAL MRI [J].
HU, XP ;
LE, TH ;
PARRISH, T ;
ERHARD, P .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :201-212
[13]  
JOSEPHS O, 1997, P 5 ANN M ISMRM VANC, P1682
[14]   Comparison of continuous overt speech fMRI using BOLD and arterial spin labeling [J].
Kemeny, S ;
Ye, FQ ;
Birn, R ;
Braun, AR .
HUMAN BRAIN MAPPING, 2005, 24 (03) :173-183
[15]   A heuristic for the degrees of freedom of statistics based on multiple variance parameters [J].
Kiebel, SJ ;
Glaser, DE ;
Friston, KJ .
NEUROIMAGE, 2003, 20 (01) :591-600
[16]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301
[17]   Physiological noise in oxygenation-sensitive magnetic resonance imaging [J].
Krüger, G ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :631-637
[18]   A signal processing model for arterial spin labeling functional MRI [J].
Liu, TT ;
Wong, EC .
NEUROIMAGE, 2005, 24 (01) :207-215
[19]   Analysis and design of perfusion-based event-related fMRI experiments [J].
Liu, TT ;
Wong, EC ;
Frank, LR ;
Buxton, RB .
NEUROIMAGE, 2002, 16 (01) :269-282
[20]   Detection power, estimation efficiency, and predictability in event-related fMRI [J].
Liu, TT ;
Frank, LR ;
Wong, EC ;
Buxton, RB .
NEUROIMAGE, 2001, 13 (04) :759-773