Monitoring regional lung ventilation by functional electrical impedance tomography during assisted ventilation

被引:42
作者
Frerichs, I [1 ]
Hahn, G
Schiffmann, H
Berger, C
Hellige, G
机构
[1] Univ Gottingen, Ctr Anesthesiol Emergency & Intens Care Med, Dept Anesthesiol Res, D-37075 Gottingen, Germany
[2] Univ Gottingen, Dept Pediat, D-37075 Gottingen, Germany
来源
ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY | 1999年 / 873卷
关键词
D O I
10.1111/j.1749-6632.1999.tb09498.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new approach in discriminating the regional air volume changes in the lungs associated with either spontaneous or mechanical ventilation during assisted ventilation is presented. Impedance data are obtained by conventional electrical impedance tomography (EIT). The data are filtered in the range of either the spontaneous or the ventilator rate and processed by the functional EIT (f-EIT) evaluation technique, whereby the variation of the respective EIT data with time is determined and imaged. EIT measurements performed in an infant during synchronized intermittent mandatory ventilation were evaluated with this method and indicated that the specific local lung volume swings related to spontaneous and mechanical inhalations can be separated and imaged as tomograms, This noninvasive approach may become useful in optimizing the ventilatory pattern during advanced forms of artificial ventilation and may help the clinician in the therapy management of individual patients.
引用
收藏
页码:493 / 505
页数:13
相关论文
共 28 条
[1]   MEASUREMENT OF BREATH AMPLITUDES - COMPARISON OF 3 NONINVASIVE RESPIRATORY MONITORS TO INTEGRATED PNEUMOTACHOGRAPH [J].
ADAMS, JA ;
ZABALETA, IA ;
STROH, D ;
SACKNER, MA .
PEDIATRIC PULMONOLOGY, 1993, 16 (04) :254-258
[2]   EFFECT OF INFANT POSITION ON BREATH AMPLITUDE MEASURED BY TRANSTHORACIC IMPEDANCE AND STRAIN-GAUGES [J].
BAIRD, TM ;
NEUMAN, MR .
PEDIATRIC PULMONOLOGY, 1991, 10 (01) :52-56
[3]  
BANNER MJ, 1992, CRITICAL CARE, P1391
[4]   QUANTIFICATION IN IMPEDANCE IMAGING [J].
BARBER, DC .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 :45-56
[5]   NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY [J].
BRADEN, DS ;
LEATHERBURY, L ;
TREIBER, FA ;
STRONG, WB .
AMERICAN HEART JOURNAL, 1990, 120 (05) :1166-1172
[6]   ASSESSMENT OF 4 ENZYME-IMMUNOASSAY KITS FOR SERUM BETA-HCG SCREENING [J].
BROWN, D ;
ALLEN, LC .
JOURNAL OF IMMUNOASSAY, 1987, 8 (01) :1-9
[7]   A RELATIONSHIP BETWEEN BIOELECTRICAL IMPEDANCE AND TOTAL-BODY WATER IN YOUNG-ADULTS [J].
DAVIES, PSW ;
JAGGER, SE ;
REILLY, JJ .
ANNALS OF HUMAN BIOLOGY, 1990, 17 (05) :445-448
[8]   Gravity-dependent phenomena in lung ventilation determined by functional EIT [J].
Frerichs, I ;
Hahn, G ;
Hellige, G .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A149-A157
[9]   Heterogeneous distribution of pulmonary ventilation in intensive care patients detected by functional electrical impedance tomography [J].
Frerichs, I ;
Golisch, W ;
Hahn, G ;
Kurpitz, M ;
Burchardi, H ;
Hellige, G .
JOURNAL OF INTENSIVE CARE MEDICINE, 1998, 13 (04) :168-173
[10]   Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography [J].
Frerichs, I ;
Hahn, G ;
Golisch, W ;
Kurpitz, M ;
Burchardi, H ;
Hellige, G .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (06) :721-726