Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate

被引:65
作者
McMahon, CP
Rocchitta, G
Serra, PA
Kirwan, SM
Lowry, JP
O'Neill, RD [1 ]
机构
[1] Univ Coll Dublin, Sch Chem & Chem Biol, Dublin 4, Ireland
[2] Univ Coll Dublin, Sch Biomol & Biomed Sci, Dublin 4, Ireland
关键词
D O I
10.1021/ac0518194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors for glutamate (Glu) were fabricated from Teflon-coated Pt wire (cylinders and disks), modified with the enzyme glutamate oxidase (GluOx) and electrosynthesized polymer PPD, poly(o-phenylenediamine). The polymer/enzyme layer was deposited in two configurations: enzyme before polymer (GluOx/PPD) and enzyme after polymer (PPD/GluOx). These four biosensor designs were characterized in terms of response time, limit of detection, Michaelis-Menten parameters for Glu (J(max) and Km(Glu)), sensitivity to Glu in the linear response region, and dependence on oxygen concentration, Km(02)Analysis showed that the two polymer/enzyme configurations behaved similarly on both cylinders and disks. Although the two geometries showed different behaviors, these differences could be explained in terms of higher enzyme loading density on the disks; in many analyses, the four designs behaved like a single population with a range of GluOx loading. Enzyme loading was the key to controlling the Km(02) values of these first generation biosensors. The counterintuitive, and beneficial, behavior that biosensors with higher GluOx loading displayed a lower oxygen dependence was explained in terms of the effects of enzyme loading on the affinity of GluOx for its anionic substrate. Some differences between the properties of surface immobilized GluOx and glucose oxidase are highlighted.
引用
收藏
页码:2352 / 2359
页数:8
相关论文
共 83 条
[1]   AMPEROMETRIC ENZYME ELECTRODES .1. THEORY [J].
ALBERY, WJ ;
BARTLETT, PN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :211-222
[2]   The effect of diffusion limitations on the response of amperometric biosensors with substrate cyclic conversion [J].
Baronas, R ;
Ivanauskas, F ;
Ivanauskas, F ;
Kulys, J .
JOURNAL OF MATHEMATICAL CHEMISTRY, 2004, 35 (03) :199-213
[3]   The influence of the enzyme membrane thickness on the response of amperometric biosensors [J].
Baronas, R ;
Ivanauskas, F ;
Kulys, J .
SENSORS, 2003, 3 (07) :248-262
[4]   MODELING OF PROCESSES IN ENZYME ELECTRODES [J].
BARTLETT, PN ;
PRATT, KFE .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) :451-462
[5]   Glutamate and its role in psychiatric illness [J].
Belsham, B .
HUMAN PSYCHOPHARMACOLOGY-CLINICAL AND EXPERIMENTAL, 2001, 16 (02) :139-146
[6]   ONLINE MEASUREMENT OF BRAIN GLUTAMATE WITH AN ENZYME/POLYMER-COATED TUBULAR ELECTRODE [J].
BERNERS, MOM ;
BOUTELLE, MG ;
FILLENZ, M .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2017-2021
[7]   ELECTROCHEMICAL STUDY OF D-GLUCOSE OXIDASE AUTO-INACTIVATION [J].
BOURDILLON, C ;
THOMAS, V ;
THOMAS, D .
ENZYME AND MICROBIAL TECHNOLOGY, 1982, 4 (03) :175-180
[8]   Ceramic-based multisite microelectrode arrays for in vivo electrochemical recordings of glutamate and other neurochemicals [J].
Burmeister, JJ ;
Gerhardt, GA .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (09) :498-502
[9]   Improved ceramic-based multisite microelectrode for rapid measurements of L-glutamate in the CNS [J].
Burmeister, JJ ;
Pomerleau, F ;
Palmer, M ;
Day, BK ;
Huettl, P ;
Gerhardt, GA .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 119 (02) :163-171
[10]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042