Characterization of scatter in cone-beam CT breast imaging: Comparison of experimental measurements and Monte Carlo simulation

被引:58
作者
Chen, Yu [1 ]
Liu, Bob [2 ]
O'Connor, J. Michael [1 ,3 ]
Didier, Clay S. [1 ,3 ]
Glick, Stephen J. [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Univ Massachusetts, Biomed Engn Program, Lowell, MA 01854 USA
关键词
Compton effect; computerised tomography; image reconstruction; Monte Carlo methods; phantoms; Rayleigh scattering; X-ray scattering; FLAT-PANEL IMAGER; X-RAY SCATTER; COMPUTED-TOMOGRAPHY; VEILING GLARE; RADIATION; MAMMOGRAPHY; DETECTORS; QUALITY; TOOLKIT; PHYSICS;
D O I
10.1118/1.3077122
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
It is commonly understood that scattered radiation in x-ray computed tomography (CT) degrades the reconstructed image. As a precursor to developing scatter compensation methods, it is important to characterize this scatter using both empirical measurements and Monte Carlo simulations. Previous studies characterizing scatter using both experimental measurements and Monte Carlo simulations have been reported in diagnostic radiology and conventional mammography. The emerging technology of cone-beam CT breast imaging (CTBI) differs significantly from conventional mammography in the breast shape and imaging geometry, aspects that are important factors impacting the measured scatter. This study used a bench-top cone-beam CTBI system with an indirect flat-panel detector. A cylindrical phantom with equivalent composition of 50% fibroglandular and 50% adipose tissues was used, and scatter distributions were measured by beam stop and aperture methods. The GEANT4-based simulation package GATE was used to model x-ray photon interactions in the phantom and detector. Scatter to primary ratio (SPR) measurements using both the beam stop and aperture methods were consistent within 5% after subtraction of nonbreast scatter contributions and agree with the low energy electromagnetic model simulation in GATE. The validated simulation model was used to characterize the SPR in different CTBI conditions. In addition, a realistic, digital breast phantom was simulated to determine the characteristics of various scatter components that cannot be separated in measurements. The simulation showed that the scatter distribution from multiple Compton and Rayleigh scatterings, as well as from the single Compton scattering, has predominantly low-frequency characteristics. The single Rayleigh scatter was observed to be the primary contribution to the spatially variant scatter component.
引用
收藏
页码:857 / 869
页数:13
相关论文
共 35 条
[1]
GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]
Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[3]
Review of particle physics [J].
Amsler, C. ;
Doser, M. ;
Antonelli, M. ;
Asner, D. M. ;
Babu, K. S. ;
Baer, H. ;
Band, H. R. ;
Barnett, R. M. ;
Bergren, E. ;
Beringer, J. ;
Bernardi, G. ;
Bertl, W. ;
Bichsel, H. ;
Biebel, O. ;
Bloch, P. ;
Blucher, E. ;
Blusk, S. ;
Cahn, R. N. ;
Carena, M. ;
Caso, C. ;
Cecccci, A. ;
Chakraborty, D. ;
Chen, M. -C. ;
Chivukula, R. S. ;
Cowan, G. ;
Dahl, O. ;
D'Ambrosio, G. ;
Damour, T. ;
de Gouvea, A. ;
DeGrand, T. ;
Dobrescu, B. ;
Drees, M. ;
Edwards, D. A. ;
Eidelman, S. ;
Elvira, V. D. ;
Erler, J. ;
Ezhela, V. V. ;
Feng, J. L. ;
Fetscher, W. ;
Fields, B. D. ;
Foster, B. ;
Gaisser, T. K. ;
Garren, L. ;
Gerber, H. -J. ;
Gerbier, G. ;
Gherghetta, T. ;
Giudice, G. F. ;
Goodman, M. ;
Grab, C. ;
Gritsan, A. V. .
PHYSICS LETTERS B, 2008, 667 (1-5) :1-+
[4]
PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER [J].
BARO, J ;
SEMPAU, J ;
FERNANDEZVAREA, JM ;
SALVAT, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) :31-46
[5]
Dedicated breast CT: Radiation dose and image quality evaluation [J].
Boone, JM ;
Nelson, TR ;
Lindfors, KK ;
Seibert, JA .
RADIOLOGY, 2001, 221 (03) :657-667
[6]
Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[7]
Comparison of x-ray cross sections for diagnostic and therapeutic medical physics [J].
Boone, JM ;
Chavez, AE .
MEDICAL PHYSICS, 1996, 23 (12) :1997-2005
[8]
Chauvie S, 2001, PROCEEDINGS OF CHEP 2001, P337
[9]
Cone-beam volume CT breast imaging: Feasibility study [J].
Chen, B ;
Ning, R .
MEDICAL PHYSICS, 2002, 29 (05) :755-770
[10]
Scatter measurements and simulations in x-ray cone beam CT breast imaging [J].
Chen, Y. ;
Liu, B. ;
O'Connor, M. ;
Didier, C. ;
Glick, S. .
MEDICAL PHYSICS, 2007, 34 (06) :2606-2606