Personal cytometers: Slow flow or no flow?

被引:39
作者
Shapiro, Howard M.
Perlmutter, Nancy G.
机构
[1] Ctr Microbial Cytometry, W Newton, MA 02465 USA
[2] Howard M Shapiro MD PC, Newton, MA 02465 USA
关键词
CCD; fluorescence; imaging cytometry; LED;
D O I
10.1002/cyto.a.20284
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Although some manufacturers have optimistically described instruments with prices in the US$40,000 range as "personal cytometers", analogy with the personal computer suggests that the target price for a true "personal" cytometer should be under $5,000. Since such an apparatus could find a wide range of applications in cytomics in both developing and developed countries, it seemed desirable to consider its technical and economic feasibility. Methods: Using resolution targets and a variety of fluorescent bead standards immobilized on filters and/or slides, we evaluated high-intensity LEDs as fluorescence excitation sources, relatively inexpensive CCD cameras as detectors, and 35 mm camera lenses and plastic low-power microscope optics for light collection in a simple, inexpensive low-resolution imaging cytometer. Results: The components tested could be combined to produce an instrument capable of detecting fewer than 10,000 molecules of cell-associated fluorescent label, and thus applicable to a broad range of cytometric tasks. Conclusions: Given the requirements for light sources, detectors, optics, mechanics, electronics and data analysis hardware and software, and the components presently available, it should be easier to reach the desired $5,000 price point with an image cytometer than with a flow cytometer. (c) 2006 International Society for Analytical Cytology.
引用
收藏
页码:620 / 630
页数:11
相关论文
共 48 条
  • [11] Statistics of single-molecule measurements: Applications in flow-cytometry sizing of DNA fragments
    Ferris, MM
    Habbersett, RC
    Wolinsky, M
    Jett, JH
    Yoshida, TM
    Keller, RA
    [J]. CYTOMETRY PART A, 2004, 60A (01) : 41 - 52
  • [12] RAPID SIZING OF INDIVIDUAL FLUORESCENTLY STAINED DNA FRAGMENTS BY FLOW-CYTOMETRY
    GOODWIN, PM
    JOHNSON, ME
    MARTIN, JC
    AMBROSE, WP
    MARRONE, BL
    JETT, JH
    KELLER, RA
    [J]. NUCLEIC ACIDS RESEARCH, 1993, 21 (04) : 803 - 806
  • [13] An analytical system based on a compact flow cytometer for DNA fragment sizing and single-molecule detection
    Habbersett, RC
    Jett, JH
    [J]. CYTOMETRY PART A, 2004, 60A (02) : 125 - 134
  • [14] Frequency-domain fluorescence microscopy with the LED as a light source
    Herman, P
    Maliwal, BP
    Lin, HJ
    Lakowicz, JR
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 2001, 203 : 176 - 181
  • [15] Hoffman RA, 2004, CYTOM PART A, V59A, P41
  • [16] Precise CD4 T-cell counting using red diode laser excitation: For richer, for poorer
    Janossy, G
    Jani, IV
    Kahan, M
    Barnett, D
    Mandy, F
    Shapiro, H
    [J]. CYTOMETRY, 2002, 50 (02): : 78 - 85
  • [17] JELINEK L, 2001, INTEL TECHNOL J, V5, P1
  • [18] Slide-based laser scanning cytometry
    Kamentsky, LA
    Burger, DE
    Gershman, RJ
    Kamentsky, LD
    Luther, E
    [J]. ACTA CYTOLOGICA, 1997, 41 (01) : 123 - 143
  • [19] SPECTROPHOTOMETER - NEW INSTRUMENT FOR ULTRARAPID CELL ANALYSIS
    KAMENTSKY, LA
    MELAMED, MR
    DERMAN, H
    [J]. SCIENCE, 1965, 150 (3696) : 630 - +
  • [20] MICROSCOPE-BASED MULTIPARAMETER LASER SCANNING CYTOMETER YIELDING DATA COMPARABLE TO FLOW-CYTOMETRY DATA
    KAMENTSKY, LA
    KAMENTSKY, LD
    [J]. CYTOMETRY, 1991, 12 (05): : 381 - 387