A novel method for simultaneous 3D B1 and T1 mapping: the method of slopes (MoS)

被引:23
作者
Chavez, Sofia [1 ]
Stanisz, Greg J. [2 ,3 ]
机构
[1] Ctr Addict & Mental Hlth, Res Imaging Ctr, Toronto, ON M5T 1R8, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
基金
加拿大健康研究院;
关键词
B1; inhomogeneities; T1; mapping; SPGR; flip angle; spoiled-gradient-echo; RF-FIELD INHOMOGENEITIES; IN-VIVO; T-2; RELAXATION; STEADY-STATE; ACCURATE; RADIOFREQUENCY; MRI;
D O I
10.1002/nbm.2769
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
A novel three-dimensional simultaneous B1 and T1 mapping method is introduced: the method of slopes (MoS). The linearity of the spoiled gradient recalled echo (SPGR) signal vs flip angle relation is exploited: B1 mapping is achieved by a two-point extrapolation to signal null with a correction scheme while T1 mapping uses the slopes of the SPGR signal vs flip angle curves near the origin and near the signal null. This new method improves upon the existing variable flip angle (VFA) T1-mapping method in that (i) consistency between B1 and T1 maps is ensured (ii) the sampling scheme is T1-independent (iii) the noise bias and singularity, associated with using a linear form for the SPGR signal equation, is eliminated by using the full equation. The method is shown to yield accurate and robust results via simulations. Initial estimates of B1 and T1 values are obtained from three data points via simple computations and straight line approximations. Initial estimates of B1 values, for a range of values, are shown to be accurate due to the proposed B1 correction scheme. The accuracy and robustness of T1 values is achieved via a non-linear fitting algorithm which includes a fourth data point sampled at high SNR. The MoS was validated by comparing resulting B1 and T1 maps with those obtained using other standard methods. Finally, the ability to obtain brain B1 and T1 maps using the MoS was demonstrated by in vivo experiments. The MoS is expected to perform well on other motion-free anatomical regions as well. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:1043 / 1055
页数:13
相关论文
共 31 条
[1]
Detection of Apoptotic Cell Death In Vitro in the Presence of Gd-DTPA-BMA [J].
Bailey, Colleen ;
Giles, Anoja ;
Czarnota, Gregory J. ;
Stanisz, Greg J. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) :46-55
[2]
A Robust Methodology for In Vivo T1 Mapping [J].
Barral, Joelle K. ;
Gudmundson, Erik ;
Stikov, Nikola ;
Etezadi-Amoli, Maryam ;
Stoica, Petre ;
Nishimura, Dwight G. .
MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (04) :1057-1067
[3]
Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity [J].
Cheng, HLM ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :566-574
[4]
Signal to noise measurements in magnitude images from NMR phased arrays - (vol 38, pg 852, 1997) [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :219-219
[5]
Saturated double-angle method for rapid B1 plus mapping [J].
Cunningham, Charles H. ;
Pauly, John M. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1326-1333
[6]
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state [J].
Deoni, SCL ;
Rutt, BK ;
Peters, TM .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) :515-526
[7]
High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI) [J].
Deoni, Sean C. L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) :1106-1111
[8]
Artifacts in 3-T MRI: Physical background and reduction strategies [J].
Dietrich, Olaf ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) :29-35
[9]
Fast, accurate, and precise mapping of the RF field in vivo using the 180° signal null [J].
Dowell, Nicholas G. ;
Tofts, Paul S. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) :622-630
[10]
TriTone:: a radiofrequency field (B1)-insensitive T1 estimator for MRI at high magnetic fields [J].
Fleysher, Roman ;
Fleysher, Lazar ;
Liu, Songtao ;
Gonen, Oded .
MAGNETIC RESONANCE IMAGING, 2008, 26 (06) :781-789