Volumetric and dosimetric evaluation of radiation treatment plans:: Radiation conformity index

被引:135
作者
Knöös, T [1 ]
Kristensen, I [1 ]
Nilsson, P [1 ]
机构
[1] Univ Lund Hosp, Dept Radiat Phys, Div Radiat Therapy Phys, S-22185 Lund, Sweden
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 42卷 / 05期
关键词
radiation therapy; treatment planning; conformal therapy; three-dimensional; conformity index;
D O I
10.1016/S0360-3016(98)00239-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The use of conformal radiation therapy has grown substantially during the last years since three-dimensional (3D) treatment planning systems with beams-eye-view planning has become commercially available. We studied the degree of conformity reached in clinical routines for some common diagnoses treated at our department by calculating a radiation conformity index (RCI), Methods and Materials: The radiation conformity index, determined as the ratio between the target volume (PTV) and the irradiated volume, has been evaluated for 57 patients treated with 3D treatment plans. Results and Conclusion: The RCI was found to vary from 0.3 to 0.6 (average 0.4), a surprisingly low figure. The higher RCI is typical for pelvic treatments (e.g., prostate) and stereotactic treatments. The lower RCI is found for extended tumors, such as mammary carcinomas where the adjacent nodes are included, The latter is also valid for most lung cancer patients studied. The RCI gives a consistent method for quantifying the degree of conformity based on isodose surfaces and volumes. Care during interpretation of RCI must always be taken, since small changes in the minimum dose can dramatically change the treated volume. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:1169 / 1176
页数:8
相关论文
共 27 条
[11]   LIMITATIONS OF A PENCIL BEAM APPROACH TO PHOTON DOSE CALCULATIONS IN THE HEAD AND NECK REGION [J].
HURKMANS, C ;
KNOOS, T ;
NILSSON, P ;
SVAHNTAPPER, G ;
DANIELSSON, H .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :74-80
[12]   Dosimetric verification of open asymmetric photon fields calculated with a treatment planning system based on dose-to-energy-fluence concepts [J].
Hurkmans, C ;
Knoos, T ;
Nilsson, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08) :1277-1290
[13]   A MONO ISOCENTRIC TECHNIQUE FOR BREAST AND REGIONAL NODAL THERAPY USING DUAL ASYMMETRIC JAWS [J].
KLEIN, EE ;
TAYLOR, M ;
MICHALETZLORENZ, M ;
ZOELLER, D ;
UMFLEET, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :753-760
[14]   COMPARISON OF MEASURED AND CALCULATED ABSORBED DOSES FROM TANGENTIAL IRRADIATION OF THE BREAST [J].
KNOOS, T ;
AHLGREN, L ;
NILSSON, M .
RADIOTHERAPY AND ONCOLOGY, 1986, 7 (01) :81-88
[15]   THE DOSIMETRIC VERIFICATION OF A PENCIL BEAM BASED TREATMENT PLANNING SYSTEM [J].
KNOOS, T ;
CEBERG, C ;
WEBER, L ;
NILSSON, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10) :1609-1628
[16]   LIMITATIONS OF A PENCIL BEAM APPROACH TO PHOTON DOSE CALCULATIONS IN LUNG-TISSUE [J].
KNOOS, T ;
AHNESJO, A ;
NILSSON, P ;
WEBER, L .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (09) :1411-1420
[17]  
KNOOS T, 1997, P 12 INT C US COMP R
[18]   Comparison between dose values specified at the ICRU reference point and the mean dose to the planning target volume [J].
Kukolowicz, PF ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (03) :271-277
[19]  
LAMM IL, 1987, USE COMPUTERS RAD TH, P257
[20]   Lateral rectal shielding reduces late rectal morbidity following high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: Further evidence for a significant dose effect [J].
Lee, WR ;
Hanks, GE ;
Hanlon, AL ;
Schultheiss, TE ;
Hunt, MA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :251-257