Electrochemical techniques for lab-on-a-chip applications

被引:122
作者
Nyholm, L [1 ]
机构
[1] Uppsala Univ, Angstrom Lab, Dept Chem Mat, SE-75121 Uppsala, Sweden
关键词
D O I
10.1039/b415004j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During the last few years there has been a rapid increase in the use of electrochemical reactions in lab-on-a-chip devices. This development, which has so far mainly focussed on electrochemical detection in chip-based capillary electrophoresis, can be explained by the fact that electrochemical techniques and devices are particularly well-suited for inclusion in lab-on-a-chip systems. The most important reason for this is that the required electrodes can readily be manufactured and miniaturised without loss of analytical performance using conventional microfabrication methods. In this Research Highlight article, the developments during the last three years concerning electrochemical techniques for lab-on-a-chip applications are discussed, with particular focus on emerging electrochemical methods for sample clean-up and preconcentration, electrochemical derivatisation and electrochemical detection in chip-based capillary electrophoresis.
引用
收藏
页码:599 / 605
页数:7
相关论文
共 59 条
[31]   Microfabricated on-chip-type electrochemical flow immunoassay system for the detection of histamine released in whole blood samples [J].
Lim, TK ;
Ohta, H ;
Matsunaga, T .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3316-3321
[32]  
LINCHTENBERG J, 2002, ELECTROPHORESIS, V23, P3769
[33]   Chemiluminescence detection for a microchip capillary electrophoresis system fabricated in poly(dimethylsiloxane) [J].
Liu, BF ;
Ozaki, M ;
Utsumi, Y ;
Hattori, T ;
Terabe, S .
ANALYTICAL CHEMISTRY, 2003, 75 (01) :36-41
[34]   Characterization of electrode fouling and surface regeneration for a platinum electrode on an electrophoresis microchip [J].
Manica, DP ;
Mitsumori, Y ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 2003, 75 (17) :4572-4577
[35]   In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat [J].
Martin, RS ;
Ratzlaff, KL ;
Huynh, BH ;
Lunte, SM .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1136-+
[36]   A ceramic electrochemical microreactor for the methoxylation of methyl-2-furoate with direct mass spectrometry coupling [J].
Mengeaud, V ;
Bagel, O ;
Ferrigno, R ;
Girault, HH ;
Haider, A .
LAB ON A CHIP, 2002, 2 (01) :39-44
[37]   On-column electrochemical detection for microchip capillary electrophoresis [J].
Osbourn, DM ;
Lunte, CE .
ANALYTICAL CHEMISTRY, 2003, 75 (11) :2710-2714
[38]   Microchip capillary electrophoresis with an integrated indium tin oxide electrode-based electrochemiluminescence detector [J].
Qiu, HB ;
Yan, JL ;
Sun, XH ;
Liu, JF ;
Cao, WD ;
Yang, XR ;
Wang, EK .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5435-5440
[39]   On-line electrochemical tagging of cysteines in proteins during nanospray [J].
Rohner, TC ;
Rossier, JS ;
Girault, HH .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (09) :695-700
[40]   Polymer microspray with an integrated thick-film microelectrode [J].
Rohner, TC ;
Rossier, JS ;
Girault, HH .