Multi-analyte procedures for screening for and quantification of drugs in blood, plasma, or serum by liquid chromatography-single stage or tandem mass spectrometry (LC-MS or LGMS/MS) relevant to clinical and forensic toxicology

被引:141
作者
Maurer, HH [1 ]
机构
[1] Univ Saarland, Dept Expt & Clin Toxicol, Inst Expt & Clin Pharmacol & Toxicol, D-66421 Homburg, Saar, Germany
关键词
screening; quantification; drugs; liquid chromatography; mass spectrometry;
D O I
10.1016/j.clinbiochem.2005.01.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
This paper reviews multi-analyte procedures for screening and quantification :of drugs in blood, plasma, or serum using liquid chromatography Coupled with a single stage or tandem mass spectrometer (LC-MS, LC-MS/MS). These procedures are relevant tools in clinical and forensic toxicology, and cover analysis of aniphetarnines, cocaine, hallucinogens, opioids, anesthetics, hypnotics, benzodiazepines, antidepressants, neuroleptics, antihistamines, sulfonylurea-type antidiabetics, beta-blockers, and other cardiac drugs. Basic information on the procedures is given in two tables and multi-analyte screening, identification, and quantification are illustrated in three figures. A critical discussion on the pros and cons of such LC-MS procedures is also included. (c) 2005 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:310 / 318
页数:9
相关论文
共 54 条
[31]   Position of chromatographic techniques in screening for detection of drugs or poisons in clinical and forensic toxicology and/or doping control [J].
Maurer, HH .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (11) :1310-1324
[32]  
MAURER HH, UNPUB APCI ELECTROSP
[33]  
MAURER HH, 2000, MASS SPECTRAL GC D 4, P3
[34]   Drugs of abuse monitoring in blood for control of driving under the influence of drugs [J].
Moeller, MR ;
Kraemer, T .
THERAPEUTIC DRUG MONITORING, 2002, 24 (02) :210-221
[35]   Determination of paramethoxyamphetamine and other amphetamine-related designer drugs by liquid chromatography/sonic spray ionization mass spectrometry [J].
Mortier, KA ;
Dams, R ;
Lambert, WE ;
De Letter, EA ;
Van Calenbergh, S ;
De Leenheer, AP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (09) :865-870
[36]   Pitfalls associated with liquid chromatography/electrospray tandem mass spectrometry in quantitative bioanalysis of drugs of abuse in saliva [J].
Mortier, KA ;
Clauwaert, KM ;
Lambert, WE ;
Van Bocxlaer, JF ;
Van den Eeckhout, EG ;
Van Peteghem, CH ;
De Leenheer, AP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (18) :1773-1775
[37]   Ion suppression effects in liquid chromatography-electrospray-ionisation transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries [J].
Müller, C ;
Schäfer, P ;
Störtzel, M ;
Vogt, S ;
Weinmann, W .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01) :47-52
[38]   Progress in liquid chromatography-mass spectrometry instrumentation and its impact on high-throughput screening [J].
Niessen, WMA .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :413-436
[39]   Screening for and validated quantification of amphetamines and of amphetamine- and piperazine-derived designer drugs in human blood plasma by gas chromatography/mass spectrometry [J].
Peters, FT ;
Schaefer, S ;
Staack, RF ;
Kraemer, T ;
Maurer, HH .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (06) :659-676
[40]   Bioanalytical method validation and its implications for forensic and clinical toxicology - A review [J].
Peters, FT ;
Maurer, HH .
ACCREDITATION AND QUALITY ASSURANCE, 2002, 7 (11) :441-449