Flow velocity estimation using joint Spectral and Time Domain Optical Coherence Tomography

被引:151
作者
Szkulmowski, Maciej [1 ]
Szkulmowska, Anna [1 ]
Bajraszewski, Tomasz [1 ]
Kowalczyk, Andrzej [1 ]
Wojtkowski, Maciej [1 ]
机构
[1] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
来源
OPTICS EXPRESS | 2008年 / 16卷 / 09期
关键词
D O I
10.1364/OE.16.006008
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a modified method of acquisition and analysis of Spectral Optical Coherence Tomography (SOCT) data to provide information about flow velocities. The idea behind this method is to acquire a set of SOCT spectral fringes dependent on time followed by a numerical analysis using two independent Fourier transformations performed in time and optical frequency domains. Therefore, we propose calling this method as joint Spectral and Time domain Optical Coherence Tomography ( joint STdOCT). The flow velocities obtained by joint STdOCT are compared with the ones obtained by known, phase-resolved SOCT. We observe that STdOCT estimation is more robust for measurements with low signal to noise ratio (SNR) as well as in conditions of close-to-limit velocity measurements. We also demonstrate that velocity measurement performed with STdOCT method is more sensitive than the one obtained by the phase-resolved SOCT. The method is applied to biomedical imaging, in particular to in vivo measurements of retinal blood circulation. The applicability of STdOCT different measurement modes for in vivo examinations, including 1, 5 and 40 mu s of CCD exposure time, is discussed. (c) 2008 Optical Society of America.
引用
收藏
页码:6008 / 6025
页数:18
相关论文
共 27 条
[21]   Full range complex spectral optical coherence tomography technique in eye imaging [J].
Wojtkowski, M ;
Kowalczyk, A ;
Leitgeb, R ;
Fercher, AF .
OPTICS LETTERS, 2002, 27 (16) :1415-1417
[22]   In vivo human retinal imaging by Fourier domain optical coherence tomography [J].
Wojtkowski, M ;
Leitgeb, R ;
Kowalczyk, A ;
Bajraszewski, T ;
Fercher, AF .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) :457-463
[23]   Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography [J].
Yasuno, Y ;
Makita, S ;
Endo, T ;
Aoki, G ;
Itoh, M ;
Yatagai, T .
APPLIED OPTICS, 2006, 45 (08) :1861-1865
[24]   Birefringence imaging of human skin by polarization-sensitive spectral interferometric optical coherence tomography [J].
Yasuno, Y ;
Makita, S ;
Sutoh, Y ;
Itoh, M ;
Yatagai, T .
OPTICS LETTERS, 2002, 27 (20) :1803-1805
[25]   Frequency estimation precision in Doppler optical coherence tomography using the Cramer-Rao lower bound [J].
Yazdanfar, S ;
Yang, CH ;
Sarunic, MV ;
Izatt, JA .
OPTICS EXPRESS, 2005, 13 (02) :410-416
[26]   Motion artifacts in optical coherence tomography with frequency-domain ranging [J].
Yun, SH ;
Tearney, GJ ;
de Boer, JF ;
Bouma, BE .
OPTICS EXPRESS, 2004, 12 (13) :2977-2998
[27]   Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity [J].
Zhao, YH ;
Chen, ZP ;
Saxer, C ;
Xiang, SH ;
de Boer, JF ;
Nelson, JS .
OPTICS LETTERS, 2000, 25 (02) :114-116