Pulmonary nodules: 3D volumetric measurement with multidetector CT-Effect of intravenous contrast medium

被引:32
作者
Honda, Osamu
Johkoh, Takeshi
Sumikawa, Hiromitsu
Inoue, Atsuo
Tomiyama, Noriyuki
Mihara, Naoki
Fujita, Yuka
Tsubamoto, Mitsuko
Yanagawa, Masahiro
Daimon, Tadahisa
Natsag, Javzandulam
Nakamura, Hironobu
机构
[1] Osaka Univ, Grad Sch Med, Dept Radiol, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Med Phys, Suita, Osaka 5650871, Japan
关键词
D O I
10.1148/radiol.2453062116
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To retrospectively evaluate the effect of contrast medium on the three-dimensional volumetric measurement of pulmonary nodules. Materials and Methods: The study was approved by the local institutional review committee, with waiver of informed consent. Sixty pulmonary nodules in 60 patients (17 women, 43 men; age range, 29-82 years) were imaged before and after administration of contrast medium with a 64-channel multidetector computed tomographic (CT) scanner; reconstructed images with a section thickness of 0.625 mm were obtained by using a bone algorithm and a standard algorithm. Volumetric measurements of pulmonary nodules were performed by using commercially available software, and the postcontrast volume ratio was calculated by dividing the postcontrast volume by the precontrast volume. Precontrast and postcontrast volumes were then analyzed by using a Wilcoxon signed rank test. Results: The median measured volumes of pulmonary nodules were 817 mm(3) (precontrast imaging, bone algorithm), 887 mm(3) (postcontrast imaging, bone algorithm), 812 mm(3) (precontrast imaging, standard algorithm), and 855 mm(3) (postcontrast imaging, standard algorithm). The measured volumes obtained with the bone algorithm were significantly larger than those obtained with the standard algorithm, both before and after administration of contrast medium (P < .01); with both the standard algorithm and the bone algorithm, the measured postcontrast volumes were significantly larger than the precontrast volumes (P < .01). The postcontrast volume ratio was more than 1.0 in 45 cases (75%) when the bone algorithm was used and in 53 cases (88%) when the standard algorithm was used. The mean postcontrast volume ratio was 1.054 with the bone algorithm and 1.065 with the standard algorithm. Conclusion: The measured volume of pulmonary nodules obtained by using three-dimensional volumetric software increased after administration of contrast medium. Moreover, the measured volume of pulmonary nodules that was obtained with the bone algorithm was larger than that obtained with the standard algorithm, regardless of whether contrast medium was used.
引用
收藏
页码:881 / 887
页数:7
相关论文
共 20 条
[1]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]
Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy [J].
Goo, JM ;
Tongdee, T ;
Tongdee, R ;
Yeo, K ;
Hildebolt, CF ;
Bae, KT .
RADIOLOGY, 2005, 235 (03) :850-856
[3]
Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements [J].
Goodman, LR ;
Gulsun, M ;
Washington, L ;
Nagy, PG ;
Piacsek, KL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (04) :989-994
[4]
Solitary pulmonary nodule: Characterization with combined wash-in and washout features at dynamic multi-detector row CT [J].
Jeong, YJ ;
Lee, KS ;
Jeong, SY ;
Chung, MJ ;
Shim, SS ;
Kim, H ;
Kwon, OJ ;
Kim, S .
RADIOLOGY, 2005, 237 (02) :675-683
[5]
Effect of blood vessels on measurement of nodule volume in a chest phantom [J].
Ko, JP ;
Marcus, R ;
Bomsztyk, E ;
Babb, JS ;
Stefanescu, C ;
Kaur, M ;
Naidich, DP ;
Rusinek, H .
RADIOLOGY, 2006, 239 (01) :79-85
[6]
Small pulmonary nodules: Volume measurement at chest CT - Phantom study [J].
Ko, JP ;
Rusinek, H ;
Jacobs, EL ;
Babb, JS ;
Betke, M ;
McGuinness, G ;
Naidich, DP .
RADIOLOGY, 2003, 228 (03) :864-870
[7]
Murakami Tadashi, 2004, Radiat Med, V22, P287
[8]
Pulmonary nodules: Preliminary experience with three-dimensional evaluation [J].
Revel, MP ;
Lefort, C ;
Bissery, A ;
Bienvenu, M ;
Aycard, L ;
Chatellier, G ;
Frija, G .
RADIOLOGY, 2004, 231 (02) :459-466
[9]
Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? [J].
Revel, MP ;
Bissery, A ;
Bienvenu, M ;
Aycard, L ;
Lefort, C ;
Frija, G .
RADIOLOGY, 2004, 231 (02) :453-458
[10]
Usefulness of morphological characteristics for the differentiation of benign from malignant solitary pulmonary lesions using HRCT [J].
Seemann, MD ;
Staebler, A ;
Beinert, T ;
Dienemann, H ;
Obst, B ;
Matzko, M ;
Pistitsch, C ;
Reiser, MF .
EUROPEAN RADIOLOGY, 1999, 9 (03) :409-417