Surface scanning analysis of planar arrays of analytes with desorption electrospray ionization-mass spectrometry

被引:58
作者
Pasilis, Sofie P. [1 ]
Kertesz, Vilmos [1 ]
Van Berkel, Gary J. [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem Sci, Organ & Biol Mass Spectromet Grp, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac070527v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analysis of analytes deposited on, separated on, or otherwise distributed about a planar surface using desorption electrospray ionization mass spectrometry in a surface scanning sampling mode was investigated. The physical regions of the surface-impacting solvent/gas jet desorption/ionization plume were described. Under the conditions typical for desorption electrospray ionization used here, the impact plume formed an elliptical desorption/ionization region on the surface. Most effective desorption/ionization was obtained from a smaller elliptical area within the larger impact region that was centered on a point on-axis from the sprayer tip to the surface. Maximum signal from a given amount of material on a surface was observed with proper plume and sample alignment when the diameter of the sample spot was less than the diameter of the central high-efficiency desorption/ionization region of the impact plume. Solvent and gas flow out of this high-efficiency desorption/ionization region was found to limit analyte accessibility to this region via a "washing effect" when analytes were on smooth surfaces or on surfaces for which the analyte had little affinity. As such, the direction of surface scanning and scan speed during an analysis was found to be important for maximizing signal levels and signal reproducibility on particular surface types. Overall, the results presented illustrate means to improve analysis of sample spots on various types of surfaces using desorption electrospray ionization mass spectrometry in a surface scanning mode.
引用
收藏
页码:5956 / 5962
页数:7
相关论文
共 11 条
[1]   Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387
[2]   Desorption electrospray ionization mass spectrometry for high-throughput analysis of pharmaceutical samples in the ambient environment [J].
Chen, HW ;
Talaty, NN ;
Takáts, Z ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :6915-6927
[3]   Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570
[4]   Capillary flow as the cause of ring stains from dried liquid drops [J].
Deegan, RD ;
Bakajin, O ;
Dupont, TF ;
Huber, G ;
Nagel, SR ;
Witten, TA .
NATURE, 1997, 389 (6653) :827-829
[5]   Development of capabilities for imaging mass spectrometry under ambient conditions with desorption electrospray ionization (DESI) [J].
Ifa, Demian R. ;
Wiseman, Justin M. ;
Song, Qingyu ;
Cooks, R. Graham .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 259 (1-3) :8-15
[6]   Mass spectrometry sampling under ambient conditions with desorption electrospray ionization [J].
Takáts, Z ;
Wiseman, JM ;
Gologan, B ;
Cooks, RG .
SCIENCE, 2004, 306 (5695) :471-473
[7]   Ambient mass spectrometry using desorption electrospray ionization (DESI):: instrumentation, mechanisms and applications in forensics, chemistry, and biology [J].
Takáts, Z ;
Wiseman, JM ;
Cooks, RG .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (10) :1261-1275
[8]   Thin-layer chromatography/desorption electrospray ionization mass spectrometry: Investigation of goldenseal alkaloids [J].
Van Berkel, Gary J. ;
Tomkins, Bruce A. ;
Kertesz, Vilmos .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :2778-2789
[9]   Automated sampling and imaging of analytes separated on thin-layer chromatography plates using desorption electrospray ionization mass spectrometry [J].
Van Berkel, Gary J. ;
Kertesz, Vilmos .
ANALYTICAL CHEMISTRY, 2006, 78 (14) :4938-4944
[10]   Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry [J].
Venter, Andre ;
Sojka, Paul E. ;
Cooks, R. Graham .
ANALYTICAL CHEMISTRY, 2006, 78 (24) :8549-8555