Polymer films as permselective coatings for H2O2-sensing electrodes

被引:50
作者
Hamdi, N
Wang, JJ
Monbouquette, HG
机构
[1] Univ Calif Los Angeles, Biomed Engn Interdept Grad Program, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Dept Chem Engn, Los Angeles, CA 90095 USA
关键词
permselective films; hydrogen peroxide sensing; overoxidized polypyrrole;
D O I
10.1016/j.jelechem.2005.04.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of amperometric biosensors based on oxidation of the H2O2 generated by in oxidase suffers frequently from interference due to electrooxidizable species in it sample. For example, an effective biosensor of this type for the neurotransmitter. glutamate, in brain extracellular fluid (ECF) should show little or no amperometric response to readily oxidizable dopamine (DA) and ascorbate (AA), which are common constituents of ECF. In this work. platinum electrodes treated with four different polymeric. permselective films are compared quantitatively in terms of sensitivity to H2O2. DA and AA and selectivity for H2O2 relative to either interferent. Here, the selectivity is defined as the ratio of the H2O2, sensitivity to the interferent sensitivity, Platinum electrodes coated with electrodeposited. overoxidized polypyrrole (OPP) and polyphenylenediamine films display H2O2 selectivities relative to AA of >= 130 and >= 240. respectively, and relative to DA of >= 100 and 80. respectively. The impressive rejection of DA by OPP films observed in this study contrasts with published results showing enhanced DA permeability of polypyrrole electrode coatings. Nafion- and polyaniline-coated electrodes give inferior selectivity performance, The OPP-treated electrodes ire judged superior overall given the best combination of H2O2 sensitivity (390 nA mu M (1) cm (2)). detection limit (0.5 mu M), response time (similar to 5 s), and stability (> 2 weeks), in addition to high H2O2 selectivities. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 66 条
[1]   A MEDIATED AMPEROMETRIC ENZYME ELECTRODE USING TETRATHIAFULVALENE AND L-GLUTAMATE OXIDASE FOR THE DETERMINATION OF L-GLUTAMIC ACID [J].
ALMEIDA, NF ;
MULCHANDANI, AK .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :353-361
[2]   THE ELECTRODEPOSITION OF POLYPYRROLE FILMS FROM AQUEOUS-SOLUTIONS [J].
ASAVAPIRIYANONT, S ;
CHANDLER, GK ;
GUNAWARDENA, GA ;
PLETCHER, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 177 (1-2) :229-244
[3]  
Bardeletti G., 1991, Biosensor Principles and Applications
[4]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[5]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .6. MICROELECTRODES FOR THE DETECTION OF L-LACTATE BASED ON FLAVOCYTOCHROME B(2) IMMOBILIZED IN A POLY(PHENOL) FILM [J].
BARTLETT, PN ;
CARUANA, DJ .
ANALYST, 1994, 119 (02) :175-180
[6]  
BARTLETT PN, 1992, J ELECTROANAL CHEM, V362, P1
[7]   ELECTROCONDUCTING CONJUGATED POLYMERS - NEW SENSITIVE MATRICES TO BUILD UP CHEMICAL OR ELECTROCHEMICAL SENSORS - A REVIEW [J].
BIDAN, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :45-56
[8]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042
[9]   DIFFERENCES IN DOPAMINE CLEARANCE AND DIFFUSION IN RAT STRIATUM AND NUCLEUS-ACCUMBENS FOLLOWING SYSTEMIC COCAINE ADMINISTRATION [J].
CASS, WA ;
GERHARDT, GA ;
MAYFIELD, RD ;
CURELLA, P ;
ZAHNISER, NR .
JOURNAL OF NEUROCHEMISTRY, 1992, 59 (01) :259-266
[10]   GLUTAMATE OXIDASE ENZYME ELECTRODES - MICROSENSORS FOR NEUROTRANSMITTER DETERMINATION USING ELECTROCHEMICALLY POLYMERIZED PERMSELECTIVE FILMS [J].
COOPER, JM ;
FOREMAN, PL ;
GLIDLE, A ;
LING, TW ;
PRITCHARD, DJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 388 (1-2) :143-149