Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy

被引:206
作者
Greer, PB [1 ]
Popescu, CC [1 ]
机构
[1] Vancouver Isl Ctr, Dept Med Phys, BC Canc Agcy, Vancouver, BC V8R 6V5, Canada
关键词
EPID; electronic portal imaging device; verification; intensity modulated radiation therapy; portal dosimetry;
D O I
10.1118/1.1582469
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of dynamic intensity modulated radiation therapy (IMRT) delivery were investigated. The EPID was utilized with continuous frame-averaging during the beam delivery. Properties studied included effect of buildup, dose linearity, field size response, sampling of rapid multileaf collimator (MLC) leaf speeds, response to dose-rate fluctuations, memory effect, and reproducibility. The dependence of response on EPID calibration and a dead time in image frame acquisition occurring every 64 frames were measured. EPID measurements were also compared to ion chamber and film for open and wedged static fields and IMRT fields. The EPID was linear with dose and dose rate, and response to MLC leaf speeds up to 2.5 cm s(-1) was found to be linear. A field size dependent response of up to 5% relative to d(max), ion-chamber measurement was found. Reproducibility was within 0.8% (1 standard deviation) for an IMRT delivery recorded at intervals over a period of one month. The dead time in frame acquisition resulted in errors in the EPID that increased with leaf speed and were over 20% for a 1 cm leaf gap moving at 1.0 cm s(-1). The EPID measurements were also found to depend on the input beam profile utilized for EPID flood-field calibration. The EPID shows promise as a device for verification of IMRT, the major limitation currently being due to dead-time in frame acquisition. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:1618 / 1627
页数:10
相关论文
共 19 条
[1]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[2]   Relative profile and dose verification of intensity-modulated radiation therapy [J].
Chang, JW ;
Mageras, GS ;
Chui, CS ;
Ling, CC ;
Lutz, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01) :231-240
[3]   Testing of dynamic multileaf collimation [J].
Chui, CS ;
Spirou, S ;
LoSasso, T .
MEDICAL PHYSICS, 1996, 23 (05) :635-641
[4]   Relative dosimetry using active matrix flat-panel imager (AMFPI) technology [J].
El-Mohri, Y ;
Antonuk, LE ;
Yorkston, J ;
Jee, KW ;
Maolinbay, M ;
Lam, KL ;
Siewerdsen, JH .
MEDICAL PHYSICS, 1999, 26 (08) :1530-1541
[5]   Commissioning of a commercially available system for intensity-modulated radiotherapy dose delivery with dynamic multileaf collimation [J].
Essers, M ;
de Langen, M ;
Dirkx, MLP ;
Heijmen, BJM .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (02) :215-224
[6]   Dosimetric characteristics of a liquid-filled electronic portal imaging device [J].
Essers, M ;
Hoogervorst, BR ;
vanHerk, M ;
Lanson, H ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1265-1272
[7]   X-RAY SCATTER IN MEGAVOLTAGE TRANSMISSION RADIOGRAPHY - PHYSICAL CHARACTERISTICS AND INFLUENCE ON IMAGE QUALITY [J].
JAFFRAY, DA ;
BATTISTA, JJ ;
FENSTER, A ;
MUNRO, P .
MEDICAL PHYSICS, 1994, 21 (01) :45-60
[8]   Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device [J].
McCurdy, BMC ;
Luchka, K ;
Pistorius, S .
MEDICAL PHYSICS, 2001, 28 (06) :911-924
[9]   X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays [J].
Munro, P ;
Bouius, DC .
MEDICAL PHYSICS, 1998, 25 (05) :689-702
[10]   The use of an electronic portal imaging system to measure portal dose and portal dose profiles [J].
Parsaei, H ;
El-Khatib, E ;
Rajapakshe, R .
MEDICAL PHYSICS, 1998, 25 (10) :1903-1909